Yes, the AD7124-8 allows continuous conversions of two channels using different reference inputs. Configure one channel to use REFIN1+/- and another channel to use REFIN2+/-. The AD7124-8 supports multiple reference inputs, and in continuous conversion mode, it can automatically sequence through the enabled channels, performing conversions on each one.