What are the differences between 3-wire and 4-wire interfaces for the MAX1464?
The MAX1464 serial interface can operate in 4-wire SPI-compatible mode or in a 3-wire mode (default on power-up). In 3-wire mode, the DI and DO lines should be connected together, forming a bidirectional data line.