AD9954: FAQ

  • Created
  • Updated
Was this helpful?
  • AD9954 power consumption on power down?

    Question I would like to know what is the AD9954's power cunsumption for each state on powerdown (refer to Table 9 of the datasheet, Rev.B Answer Please see estimated results attached for the AD9954…
  • AD9954: DACP pin connected to AGND

    Question The datasheet of the AD9954 specifies that DACBP should be decoupled to Ground. It would make sense to me to decouple it to the Analog Ground rather than the Digital Ground. It is not specified…
  • AD9954: Effect of REF CLK

    Question What is the RELATIVE level of the DDS ""spurious"" at DDS-Clock ( AD9954 at 400 MHz.) / 8 ,and DDS- Clock / 16 ? ( Ofcourse with no filtering but direct at R-DAC and single ended oputput )…
  • AD9954: RAM continuous recirculate mode, start phase information

    Question In the RAM continuous recirculate mode, what is the phase information at the very beginning of each sweep cycle? Does the phase reset to 0 at the beginning of each sweep cycle? Answer The…
  • AD9954: RAM continuous recirculate mode, start phase information

    Question In the RAM continuous recirculate mode, what is the phase information at the very beginning of each sweep cycle? Does the phase reset to 0 at the beginning of each sweep cycle? Answer The…
  • AD9954: Spur at SYSCLK/4

    Question I have used AD9954 as a clock reference, but in the output of DDS, one spur which frequency is N*Fxtal/4 (N is the PLL multiplier)exists, would you help me how to eliminate this spur. Answer…
  • AD9954: Spur at SYSCLK/4

    Question I have used AD9954 as a clock reference, but in the output of DDS, one spur which frequency is N*Fxtal/4 (N is the PLL multiplier)exists, would you help me how to eliminate this spur. Answer…
  • AD9954: Synchronization of 16 AD9954

    Question 1.Our design uses the two options described on datasheet page 30. I.e. synchronizing with SYNC_IN and SYNC_CLK signals AND a single crystal driving multiple (=16) AD9954s. Do you recommend…
  • AD9954: What is the relationship between the power consumption and the frequency of the system clock?

    Question What is the relationship between the power consumption and the frequency of the system clock? Answer Please refer to the results in the attached file.
  • PC connection cable for AD9954/PCBZ

    Question I have an evaluation board AD9954/PCBZ,but i didn't find a connection cable to the PC. So what type of cable should I usewhere I can find it? Answer The cable is not provided by Analog Devices…

Before You Switch


Switching languages will make ADI Explorer unavailable. Resume your session by switching back to English and reopening ADI Explorer.