The algorithms for the Activity Classifier, Step-Counter, and Energy Expenditure were only developed for the wrist-based applications. In the firmware version v32.9.22 of the MAXM86161, the output values…
A shift in the data read from the FIFO could be due to sub-DAC XNL error mentioned in the data sheet. The sub-DAC tag identifies that this occurred. The data sheet says: “One application of this feature…
The main difference between the MAXM86161 and the MAX86160 is that the MAXM86161 has SpO2 measurement capabilities, and therefore a red LED integrated also. Both parts have green and IR LEDs. Apart from…
This LDO powers the internal chip circuitry of the device. Page 13 of the datasheet says that when the LDO is turned off the part goes in to shutdown mode. Thus enabling the LDO actually enables the device…
This tag indicates that the sub-DAC had updated on this conversion, and it is a mechanism to show that the sub-DAC has updated which means a residual sub-DAC XNL error has shifted the resulting data. The…
As shown in the following picture, all locations are okay, but B and D are the best according to our test. We recommend users buy MAXM86161EVSYS and do some test to find which location is the best.
Less than 10 seconds. MAXM86161 is in-ear oriented, but it can also be applied to other sites of the body. And our other sensors are mainly applied to wrist, fingertip, or abdomen, not arm. The accuracy…
Out of MAX32664 versions A, B, C and D, the versions B and C are compatible with the MAXM86161. These are Maxim's best current biometric sensor hub microcontroller for in ear heart rate monitoring with…