4-Wire-Bio-Config 3 Board
Used to measure a matrix of ideal R and C components.
Has built in USB-micro connector to measure “real world” sensors.
Please refer to 4-Wire Bio Config 3 Layout and…
This community is available for customers looking for support for the ADuCM350. The applications support for the ADuCM350 consists of the ADI evaluation hardware and software, the downloadable design file…
Q: What does the ADuCM350 Evaluation Kit contain?
A:
Eval-ADUCM350EBZ motherboard. This board provides access to all of the pins on the ADuCM350. There are a number of different options for power…
Q: How to calculate current resolution ?
A: Input Current Resolution = 3.6V/2^16 x 1/1.5 x 1/RTIA = 14.6nA (assumption RTIA=2.5k Ω as in diagram below )
Q: Can I do a differential measurement using…
Q: Can ADuCM350 be used for measurement of capacitive load alone?
A: ADuCM350 cannot be used for measuring capacitive impedance alone as it would cause In-Amp loop in-stability. To maintain In-Amp…
Q: How do I start writing an AFE squence ?
A: Advise to use the example sequences in the Software Development Kit as a reference, e.g. ImpedanceMeasurement_2wire.c
Then use the ADuCM350 ASH (AFE Sequence…
Q: What is the maximum common mode ? ADC input range ? Etc
A: Please refer to the "AFE Signal Swings" section in AFE Excitation Loop chapter of UG-587 and the ADC Measurement section
in ADC Chapter…
Q: I want to change the calibration resistor (RCAL) on my board. How do I reflect this change in the Amperometric Measurement example?
A: Insert the following into AmperometricMeasurement.c (see screen…
Q: Can you do calibration on part in the field ?
A: Yes - the part has an infield calibration routine which removes offsets/gains and some switch leakage for extremely accurate performance.
The No…
1. What are the possible input sources for the CRC block?
>> The CRC accelerator can be used to compute CRC for a block of memory locations in the SRAM, flash, or any combination of memory mapped registers…