AnsweredAssumed Answered

LTC4366 -2

Question asked by Paosumer on Jun 5, 2018
Latest reply on Jun 6, 2018 by Paosumer

Hello everyone. i have a supresor circuit with LTC4366CDDB-2#PBF, it work fine when the overvoltage is about 2 seconds, but when overvoltage pass more that 2 seconds the Ltc4366-2 never restart from cool-down period.

I have to turn off the source and wait 9seconds in order to Ltc 4366 works fine again.

Vmin=10v, Vclamp=28 and Vmax=32V

 

attached circuit and all values parts. are there any mistake with the circuit?

 

Regards

Paola 

Attachments

Outcomes