DOCUMENT | ADIS16223 Datasheet, Rev. 0 http://www.analog.com/media/en/technical-documentation/data-sheets/ADIS16223.pdf |
LOCATION | Pages 15, 16 (PDF file page numbers, which are different than those at the bottom of each page) |
DESCRIPTION OF ERRORS |
With the help of StephanB , we have identified two typos in this datasheet, which both relate to the 16-bit command codes that trigger the GLOB_CMD[4] (clear DIAG_STAT flags) and GLOB_CMD[2] (self-test) routines. Please see the following graphics, which highlight the area of error and offer the correct information, in red. Page 14 (click on image for higher-resolution view): Page 15 (click on image for higher-resolution view): |
RESOLUTION | These typos will be fixed in the next revision of the datasheet (Rev. A), which we expect to be online by 11/15/2017. |