The datasheet for the MAX3083 states that the typical threshold voltage is -125mV and has a min max value of -200 and -50mV respectively. In practice you will see the threshold within this range. Similarly the value stated for the hysteresis is typical and there is no min or max guarantee. Hysteresis and threshold can be affected by common mode voltage and temperature.