There’s no power up sequence requirment for AVDD, DVDD & IOVDD.
However, we do not encourage to power (pull-high) the port pins from the controller when MAX97606 is not yet powered up. There’s a risk of damage the part and have reliability issue over time. One of the reasons is that current can back feed through internal ESD diode to DVDD/AVDD.