The datasheet Page 9, Applications Information section provides a formula for setting the current-limit threshold. This formula includes two constants, P and C, that are not mentioned in the formula section. The P and C values are provided in the Electrical Characteristics table on page 2, where P =135kV and C = 1.35kΩ. :