Errors in MAX14856/MAX14858 and MAX14852/MAX14854 datasheets.
This article refers to MAX14856/MAX14858 datasheet (document 19-7966; Rev 1; 1/17) and MAX14852/MAX14854 datasheet (document 19-7965; Rev 1; 1/17)
1. Figure 9 illustrates a HALF DUPLEX (2 wire) RS485 only circuit. Label incorrectly states FULL DUPLEX (4 wire) RS422/RS485.
2. For proper termination of a HALF DUPLEX (2 wire) RS485 circuit, a 120 ohm termination is required on BOTH ENDS of the RS485 network. Figure 9 incorrectly shows termination of 120 ohms only on one side of the RS485 network.