There are blanking requirements stated in the data sheet, and zero blanking time is not supported.
In general, CVT-RB timings are a good place to start for video timing proposals, then modified as needed…
The limits given in the data sheet EC table are per ISO10605, RD = 330Ω, CS = 150pF for Contact and Air discharge and Human Body Model, RD = 1.5kΩ, CS = 100pF, with device powered off.
This latency can be approximated to the same values given for GPIO delay (without delay compensation). For forward channel it is about 1 μs and for reverse channel it is about 6 μs for GMSL2 use-case,…
Typical value of supply current is not a reference for power supply sizing, use the maximum supply value for reference.
Typical value of supply current is an indicative value of current consumption which…
The pixel clock is the clock rate of pixels in a video stream. The following equations can be used to calculate pixel clock:
PCLK = Htotal * Vtotal * Framerate
PCLK = (Active Width) * (Active Height…
It's best to think of this terminology relative to the host processor.
For cameras or sensors, the deserializer is connected to the processor so it is "local" and the serializer connected on the other…
For MAX96717 and MAX96717F, we recommend using 1.25V internal voltage reference. The setup of these voltage references, and ADC setup, can be found in the MAX96717 User Guide.
Note: MAX96717R does not…