Article What is the Workaround for the DS2408 Power-On Reset Issue?

The DS2408 is sensitive to the slew rate of the power-on sequence and can inadvertently power up with a test mode feature enabled. The symptom of this mode is the P0 pin is stuck midway between Vcc and GND and cannot be affected by the normal ‘Channel Access Write’ command.

The following sequence will disable any test mode functions. Run this sequence after every power-on reset.
 

1-Wire Reset + Presence Pulse

Write Test Match ROM command: 96 hex

Write 64 bit ROM of DS2408

Write Exit Test Mode command: 3C hex

1-Wire Reset + Presence Pulse
 

 

Before You Switch