Article Can the Internal Oscillator in the MAX14830 be used?

We found the internal oscillator was not able to maintain it’s accuracy over lifetime.  As a result, we did not feel confident for our customers to use the internal oscillator.  Therefore we updated the datasheet and took out any information related to the internal oscillator as we do not want our customers using this feature.

 

 

 

 