Yes, there is just enough power available from Viso to power the two data channels provided that outputs on the Viso side do not have a resistive or heavily capacitive load. The primary side power is provided…
Yes, the isoPower Chipset and the data chip set are independent. You can operate them at completely different voltages is that is useful in your design. The Data and power sections do share a common ground…
Yes, with some limits. The turns-ratio in the transformer is a little higher than 1:1 so there is a small amount of voltage gain. This is enough to allow normal power supply variance at the input while…
The ADuM5x1x and ADuM6x1x parts offer less of an EMI challenge than previous isoPower devices. The main reason for this is that the new parts are targeted at lower total power, so the peak currents in…
No, the data channels are a separate chip set, so they can be run independently of what is happening with the isoPower converter. On side 1 the data channels will still draw quiescent current and drive…
Yes – These devices contain a Thermal Shutdown circuit that turns off the tank oscillator if the temperature rises to 150C. The Thermal Shutdown circuit has about 10C of hysteresis so the temperature must…
The ADuM5x1x and ADum6x1x mold compounds are qualified as material Group II allowing smaller creepage for the same working voltage. The SSOP20 packge with 5.3mm of creepage will be adequate for reinforced…
Yes, each secondary is unreferenced so you can stack two or more outputs to add the voltages. If your part contains data channels, those channels will likely need to be in the part that is connected to…