Question Can I run all of the data channels at maximum data rate simultaneously? Answer Yes, there is just enough power available from Viso to power the two data
channels provided that outputs on the…
Question Do I need to follow the recommendations of AN-0971 to achieve EMI emissions
targets? Answer The ADuM5x1x and ADuM6x1x parts offer less of an EMI challenge than previous
isoPower devices. The…
Q
The creepage is smaller on this device than the SOIC wide devices, will this limit me?
A
The ADuM5x1x and ADum6x1x mold compounds are qualified as material Group II allowing smaller creepage…
Q
Do the data shut down when the isoPower is disabled?
A
No, the data channels are a separate chip set, so they can be run independently of what is happening with the isoPower converter. On side…
Question Can the isoPower converter and the data channels operate at different voltages? Answer Yes, the isoPower Chipset and the data chip set are independent. You can
operate them at completely different…
Question Is there overload protection in the ADuM5x1x and ADuM6x1x? Answer Yes – These devices contain a Thermal shutdown circuit that turns off the tank
oscillator if the temperature rises to 150C.…
Question Can I put two parts of ADUM5010 or ADUM6010 in parallel for more power? Answer It can be done, but there is no provision for external regulation in these
devices, so the power will not be equally…
Q
Can I stack isoPower outputs to make higher voltages?
A
Yes, each secondary is unreferenced so you can stack two or more outputs to add the voltages. If your part contains data channels, those…
Question Can I synchronize the isoPower PWM signal with an external source? Answer No, the control of the PWM is completely internal to the chip, and no external
pins can affect it.