MAX31820PAR is characterized for operation without a local power supply and specification is for operation -55oC to +100oC.
MAX31820 (non PAR) is characterized for operation with a local power supply. While it is noted that it is capable of operation with parasitic power, it has not been specified or guaranteed for performance with parasitic power. The MAX31820 operating temperature specification is -55oC to +125oC.