Article ADSP-BF707 Preserve data after RESET

Please find the attached ADSP-BF707 example code to preserve data after RESET. This can be done using the snippet given below.

 

*pREG_RCU0_BCODE= BITM_RCU_BCODE_NOMEMINIT;                    /*Bypass memory initialization to preserve data after Reset*/