ADIS16223 Datasheet Errors

Document created by NevadaMark Employee on Sep 10, 2017Last modified by NevadaMark Employee on Sep 22, 2017
Version 3Show Document
  • View in full screen mode
DOCUMENT ADIS16223 Datasheet, Rev. 0
http://www.analog.com/media/en/technical-documentation/data-sheets/ADIS16223.pdf
LOCATION Pages 15, 16 (PDF file page numbers, which are different than those at the bottom of each page)
DESCRIPTION OF ERRORS

With the help of StephanB, we have identified two typos in this datasheet, which both relate to the 16-bit command codes that trigger the GLOB_CMD[4] (clear DIAG_STAT flags) and GLOB_CMD[2] (self-test) routines. Please see the following graphics, which highlight the area of error and offer the correct information, in red.

Page 14 (click on image for higher-resolution view):

 

Page 15 (click on image for higher-resolution view):

RESOLUTIONThese typos will be fixed in the next revision of the datasheet (Rev. A), which we expect to be online by 11/15/2017.
1 person found this helpful