ADuM54xx and ADuM64xx: Startup Problems

Document created by analog-archivist Employee on Feb 23, 2016Last modified by analog-archivist Employee on Feb 23, 2016
Version 2Show Document
  • View in full screen mode

My part has startup problems during Power Up

 

This startup issue looks like that described in the attached note as symptom no
2.  The solution is to reduce the capacitive load and/or add a resistive load
to avoid restart issues, as shown in figure 1.  There is a revision that is
available through distribution, with data code 11/28 or later.

Please see the symptoms in the attached document

This applies to all ADuM52xx and All ADuM64xx parts

There is a new die available which was introduced mid 2011 - please see
specific PCNs 