ADUM5010, ADUM6010 - Data shut down

Document created by analog-archivist Employee on Feb 23, 2016
Version 1Show Document
  • View in full screen mode

Do the data shut down when the isoPower is disabled?

 

No, the data channels are a separate chip set, so they can be run independently
of what is happening with the isoPower converter.  On side 1 the data channels
will still draw quiescent current and drive data to side 2.  On side 2, if
power is available from a source other than Viso, it will continue to operate
normally.  If side 2 is powered by Viso, it will shut down when Viso is
disabled, but side 1 power must be switched separately if you need low power
from the data section.  A pass transistor controlled from the Pdis signal
should be used to turn power off to Vdd1.