I set EN1 and EN2 high to disable the internal refresh and watchdog for lowest operating power. Is DC correctness guaranteed in this state?

Document created by analog-archivist Employee on Feb 23, 2016
Version 1Show Document
  • View in full screen mode

I set EN1 and EN2 high to disable the internal refresh and watchdog for lowest
operating power. Is DC correctness guaranteed in this state?

 

No, an input transition (high to low or low to high) is required to guarantee
that the ADuM144X output state matches the input state.

Attachments