Is it possible to continuously operate the ADRF6703 at any constant LO
frequency over the whole temperature range without band switching, e.g. without
out loss of phase lock?

 

The device is designed to be locked at a particular frequency, and then stay
locked (without another band calibration) as temperature is varied.