Is it possible to order a version with factory programmed output voltages?

Document created by analog-archivist Employee on Feb 23, 2016
Version 1Show Document
  • View in full screen mode

Is it possible to order a version with factory programmed output voltages?

 

No, the ADP5052 is offered as adjustable output as default version. Refer to
the ADP5052 datasheet for available factory programmable options including
fixed output options, half switching frequency setting, PWRGD options and more.
Please contact your local Analog Devices sales or distribution representative
to order a device with options other than the default options. A minimum order
quantity is necessary to create a new version product.