ADM2587E isolation ratings

Document created by analog-archivist Employee on Feb 23, 2016
Version 1Show Document
  • View in full screen mode

Two questions here:
1. Could it be used in 500Vrms AC isolation?
2. could we use meters with 20Mohm to measure the resistance between input and


1. ADM2587E's continous working voltage is 400Vrms. If you wonder higher
isolation rating, please consider ADM2687E (Viorm=600Vrms).
2. the typical resistance between input and output is 1T, I'm afraid that is
above the maximum range of your meter.