Bias Stability over 1 Year

Document created by analog-archivist Employee on Feb 23, 2016
Version 1Show Document
  • View in full screen mode

Do you have any aging data related to the one year bias stability?


The key limitation is in the ARW (Acceleration Random Walk).  For the
accelerometer in the ADIS16209, the ARW is ~30ug/sqrt(hour).  If we look at
this over a one year period, we can calculate it in the following manner:

Error = 0.00003 x sqrt(365x24) = 2.8mg