ADG508A: Enquiry for product specification

Document created by analog-archivist Employee on Feb 23, 2016
Version 1Show Document
  • View in full screen mode



Information enquires:
1.) Thermal Resistance from Junction to case (Theta Jc),
2.) Maximum junction temperature


Pls kindly note that I would only need Theta Jc and not Theta
Ja(Junction-to-air).

 

105˚C is the max case temperature for the ADG508AKR. I have calculated it using
a TJ of 125C.
(Pd = 470mW; Rjc =42.9 °C/W; Tj = 125°C) for Tc = Tj - Pd x Rjc = 104.79

Attachments

    Outcomes