confusing redundant temperature spec info in datasheet

Document created by analog-archivist Employee on Feb 23, 2016
Version 1Show Document
  • View in full screen mode

The datasheet is confusing. is the temperature spec +85C or +125C

it mentions the Y suffix as industrial +125C as the abosulte max rating
section. But no Y generic model can be ordered. However all default part is now
spece to +125C

 

It appears the ADG1608 data sheet rev.0. have extra redundant info. Please use
the ordering guide section for operating temperature range. As in Table 7 the
industrial Y series is mentioned (125 degrees C) but not being sold.

Author responsible for this data sheet had been notified for correlation and
updates.