ADCMP602 output "weakly" pulled up in shutdown mode

Document created by analog-archivist Employee on Feb 23, 2016
Version 1Show Document
  • View in full screen mode

The datasheet doesn't mention the status of the output pin in case the shutdown
SDN input has been activated. What's the expected behaviour in this case? I
suspect the output pin enters tri state mode. Is this correct?

 

The ADCMP602 shutdown mode is to save power achieved by reducing many of the
internal bias currents. 
It does not put the part in a tri-state condition. As such, the ADCMP602
outputs will be “weakly” pulled up.