Maintaining the precision performance of the ADA4528-x

Document created by analog-archivist Employee on Feb 23, 2016
Version 1Show Document
  • View in full screen mode

What precautions do I have to take to maintain the precision performance of the
amplifier?

 

Properly bypass the power supplies and keep the supply traces short to minimize
power supply disturbances. Connect bypass capacitors as close as possible to
the device supply pins. Keep the  printed circuit board clean and free of
moisture. Refer to Page 17 of the data sheet for more information.

Attachments

    Outcomes