Is Data Valid Time (tDV) of 12nS for AD9959 correct? Or should it be 1.2nS instead?

Document created by analog-archivist Employee on Feb 23, 2016
Version 1Show Document
  • View in full screen mode

Data Valid Time (tDV) is indicated as 12ns minimum (refer to Table 25 On page
31 of the AD9959 RevB data-sheet. This can't be true with respect to the fast
5ns serial-data clock? Should it be 1.2ns instead?

 

12nS is correct. This timing is for a read operation (Figure 42). Read
operations were not designed for speed like the write operation. 12ns is what
the designers targeted as the minimum.