AD9744: Maximum sample rate

Document created by analog-archivist Employee on Feb 23, 2016
Version 1Show Document
  • View in full screen mode

In the data sheet of AD9744, the update rate is given as 210Msps, but in the
brief introduction and in the DACs table it is given  165Msps.
Are 210 Msps and 160Msps tow different DACs? Could you please clear this
ambiguity.

 

The AD9744 maximum sample rate specification has been revised upwards from
165MSPS to 210MSPS and this is reflected in the latest version of the datasheet
(revB).

The maximum sample rate for all versions of the AD9744 is now 210MSPS.

Attachments

    Outcomes