AD9513: figure 25 full scale delay datasheet error

Document created by analog-archivist Employee on Feb 23, 2016Last modified by analog-archivist Employee on Feb 23, 2016
Version 2Show Document
  • View in full screen mode

In datasheet, it full scale delay should be 1.8ns,6.0ns,11.6ns, programmable.
But, there is fig. 25 shows the delay is 1.5/5.0/10ns.
Which one is correct?

 

The spec table is correct. The spec table undergoes a detailed design review
prior to release. It is possible that the figure 25 was never updated with the
final delay numbers. This will be corrected at the next revision of this
datasheet.

Outcomes