ADS620 Datasheet rev.H fig 45 error

Document created by analog-archivist Employee on Feb 23, 2016
Version 1Show Document
  • View in full screen mode

In the AD620 Datasheet rev.H fig 45. The AD620 supply on the Vs terminal (-15V)
is wrongly connected to the ground.

 

This error in Fig 45 will be corrected in the next revision of this datasheet.