Why the AD7091R ,when I measure the Idrive current during operational mode do I get higher than the 20uA as quoted in the maximum rating in the data sheet?

Document created by jcolao Employee on Jun 18, 2015
Version 1Show Document
  • View in full screen mode

The conditions for Idrive current measurements in the data sheet are for a Vin = 0V. This means that the output codes are all 0s. If the output codes are toggling the current required to change the state of the SDO pin is increased and the Idrive current is increased. The worst case current   will be when the conversion result is 101010.

 

The current drawn in a particular application will also depend on the capacitive load on the SDO line.