ADuM144x Low Power Digital Isolators: I set EN1 and EN2 high to disable the internal refresh and watchdog for lowest operating power. Is DC correctness guaranteed in this state?

Document created by rdowning on Nov 13, 2013
Version 1Show Document
  • View in full screen mode

No, an input transition (high to low or low to high) is required to guarantee that the ADuM144X output state matches the input state.