FAQ: ADIS16364 not working on EVAL-ADIS

Document created by NevadaMark Employee on Oct 31, 2013
Version 1Show Document
  • View in full screen mode

Q:

When I connect my ADIS16364 device to the EVAL-ADIS system, the gyroscopes are all pegged to 409 deg/sec and the device does not seem to be working. Any ideas?

------------------------------------------------------------------------------------------------------------------------------------------------------

A:

Yes, check JP2. For the ADIS16360, ADIS16362, ADIS16364, ADIS16365, ADIS16367, ADIS16385, ADIS16400, ADIS16405 and ADIS16407, JP2 must be OPEN for proper operation. For more information on using the devices on the EVAL-ADIS, please visit the following Wiki Guide:

http://wiki.analog.com/resources/eval/user-guides/inertial-mems/imu/adis1636x

Attachments

    Outcomes