Article AD5141: Operation below 2.3VDD

Q 

Can the part operate below 2.3V VDD?

 

A 

The part has not been characterizing below 2.3V due to EEPROM functionality
restrictions. In other words, the EEPROM cannot be programmed below this supply
voltage.