Analog.com Analog Dialogue Wiki 简体中文
EngineerZone
EngineerZone
  • Log In
  • Site
  • Search
  • User
  • Support

    Popular Forums

    • RF and Microwave
    • Power Management
    • Video
    • FPGA Reference Designs
    • Precision ADCs
    • Linux Software Drivers
    • SigmaDSP Processors & SigmaStudio Dev. Tool

    Product Forums

    • A2B
    • Amplifiers
    • Analog Microcontrollers
    • Clock and Timing
    • Data Converters
    • Direct Digital Synthesis (DDS)
    • Energy Monitoring and Metering
    • Interface and Isolation
    • MEMS Inertial Sensors
    • Processors and DSP
    • Switches/Multiplexers
    • Temperature Sensors
    • Voltage References
    View All

    Application Forums

    • Audio
    • Automated Test Equipment (ATE)
    • Condition-Based Monitoring
    • Depth, Perception & Ranging Technologies
    • Embedded Vision Sensing
    • Motor Control Hardware Platforms
    • Optical Sensing
    • Precision Technology Signal Chains
    • Video
    • Wireless Sensor Networks Reference Library

    Design Center Forums

    • ACE Evaluation Software
    • ADEF System Platforms
    • Design Tools and Calculators
    • FPGA Reference Designs
    • Linux Software Drivers
    • Microcontroller no-OS Drivers
    • Reference Designs
    • Signal Chain Power (SCP)
    • Software Interface Tools
    • System Demonstration Platform (SDP) Support
  • Learn

    Highlighted Webinar

    Robust Industrial Motor Encoder Signal Chain Solutions

    Recent Discussions

    • About the values of CurV1,2 displayed in the cursors frame of scopy.
    • Purpose of "Load" in Scopy signal generator configuration GUI
    • about the transient response experiment example of RL Circuit using adalm2000
    • Using ADALM1000 AIN and CHA as kelvin connection
    • I2C communication with ADALM2OOO Through Scopy

    Places

    • ADI Education Home
    • ADI Education China
    • ADI Education India
    • ADI Education Philippines
    • StudentZone (Analog Dialogue)
    • Virtual Classroom

    Latest Webinars

    • Robust Industrial Motor Encoder Signal Chain Solutions
    • Precision Low Power Measurement Solutions for Intelligent Edge
    • Advantages of Integrating Digital Power System Management (DPSM) into your Design
    • Optimizing GaN and GaAs RF Amplifier Performance Using Novel Biasing Techniques
    • Improving Switch-Mode Power Supplies Using Noise Cancelling Technology
    View All Webinars
  • Community Hub

    Challenge Yourself!

      KCC's Quizzes AQQ230 about a clock and angle puzzle
    View All

    Places

    • Community Help
    • Logic Lounge

    Resources

    • EZ Code of Conduct
    • Getting Started Guide
    • ADI: Words Matter
    • Community Help Videos
    View All
  • Blogs

    Highlighted Blogs

    Using Python To Control The Pluto Radio And Plot Data

     

    Resistance is NOT Futile

    Latest Blogs

    • What is The Continuity of Engineering?
    • Move Over Sensors: Actuators Are Entering The Smart Factory Stage
    • What To Call A Non-Compliant Item
    • How to Construct a Beamformer with the ADALM-PLUTO
    • Customize Your EZ Experience
    Read All Blogs

    ADI Blogs

    • EZ Spotlight
    • The Engineering Mind
  • Partners

    Electronic Design Services - PartnerZone

    • Boston Engineering
    • Calian, Advanced Technologies
    • Colorado Engineering Inc. (DBA CAES AT&E)
    • Clockworks Signal Processing
    • Epiq Solutions
    • Fidus
    • PalmSens
    • Richardson RFPD
    • Tri-Star Design, Inc.
    • VadaTech
    • Vanteon
    • X-Microwave
    View All
Precision ADCs
  • Data Converters
Precision ADCs
Documents AD7175-2 250kSPS, 24-bit Sigma Delta ADC
  • Forums
  • File Uploads
  • FAQs/Docs
  • Members
  • Tags
  • More
  • Cancel
  • +Documents
  • +General: FAQ
  • +AD1139: FAQ
  • +AD1556: FAQ
  • +AD1580: FAQ
  • +AD1582: FAQ
  • +AD2S1200: FAQ
  • +AD2S1205: FAQ
  • +AD2S1210: FAQ
  • +AD2S75: FAQ
  • +AD2S80: FAQ
  • +AD2S80A: FAQ
  • +AD2S82A: FAQ
  • +AD2S83: FAQ
  • +AD2S90: FAQ
  • +AD2S99: FAQ
  • +AD4110-1: FAQ
  • +AD411x: FAQ
  • +AD5940: FAQ
  • +AD598: FAQ
  • +AD650: FAQ
  • +AD652: FAQ
  • +AD654: FAQ
  • +AD7091: FAQ
  • +AD7091r: FAQ
  • +AD711: FAQ
  • +AD7124-4: FAQ
  • +AD7124-8: FAQ
  • +AD7134: FAQ
  • +AD713: FAQ
  • +AD7142: FAQ
  • +AD7147: FAQ
  • +AD7148: FAQ
  • +AD7150: FAQ
  • +AD7151: FAQ
  • -AD7175-2: FAQ
    • There are a number of filter options for the AD7175-2 – which one should I use?
    • I don't see a RESET pin on the AD7175-2, How do I reset the ADC?
    • AD7175-2 digital interface check
    • Synchronization of multiple AD7175-2 + Set ODR to 20kSPS
    • The AD7175-2 has a maximum output data rate of 250 kSPS but a channel scan rate of
    • What does the MUX_IO bit do on the AD7175-2?
    • Are there any precautions that should be taken to make the interface for the AD7175-2 more robust?
    • AD7175-2 250kSPS, 24-bit Sigma Delta ADC
    • Can the AD7175-2 be configured to settle in a single cycle?
  • +AD7176-2: FAQ
  • +AD7176: FAQ
  • +AD717x: FAQ
  • +AD7190: FAQ
  • +AD7192: FAQ
  • +AD7193: FAQ
  • +AD7195: FAQ
  • +AD719x: FAQ
  • +AD7265: FAQ
  • +AD7266: FAQ
  • +AD7280: FAQ
  • +AD7291: FAQ
  • +AD7298: FAQ
  • +AD7305: FAQ
  • +AD7321: FAQ
  • +AD7323: FAQ
  • +AD7328: FAQ
  • +AD7366-5: FAQ
  • +AD7367: FAQ
  • +AD736ARZ: FAQ
  • +AD737: FAQ
  • +AD7380 : FAQ
  • +AD7398: FAQ
  • +AD7400A: FAQ
  • +AD7401: FAQ
  • +AD7403: FAQ
  • +AD74111: FAQ
  • +AD7415: FAQ
  • +AD7416: FAQ
  • +AD7417: FAQ
  • +AD7418: FAQ
  • +AD7450: FAQ
  • +AD7475: FAQ
  • +AD7484: FAQ
  • +AD7490: FAQ
  • +AD7492: FAQ
  • +AD75019: FAQ
  • +AD7503: FAQ
  • +AD7541A: FAQ
  • +AD7546: FAQ
  • +AD7547: FAQ
  • +AD7568: FAQ
  • +AD7578: FAQ
  • +AD7606-4: FAQ
  • +AD7606: FAQ
  • +AD7606B: FAQ
  • +AD7606C: FAQ
  • +AD7608: FAQ
  • +AD7616 FAQ
  • +AD7616-P: FAQ
  • +AD7621: FAQ
  • +AD7625: FAQ
  • +AD7626: FAQ
  • +AD7631: FAQ
  • +AD7653: FAQ
  • +AD7654: FAQ
  • +AD7655: FAQ
  • +AD7656: FAQ
  • +AD7657-1: FAQ
  • +AD7663: FAQ
  • +AD7674: FAQ
  • +AD7675: FAQ
  • +AD7678: FAQ
  • +AD7682: FAQ
  • +AD7683: FAQ
  • +AD7684: FAQ
  • +AD7685: FAQ
  • +AD7688: FAQ
  • +AD7689: FAQ
  • +AD7690: FAQ
  • +AD7691: FAQ
  • +AD7705: FAQ
  • +AD7706: FAQ
  • +AD7707: FAQ
  • +AD7708: FAQ
  • +AD7709: FAQ
  • +AD7710: FAQ
  • +AD7711A: FAQ
  • +AD7712: FAQ
  • +AD7713: FAQ
  • +AD7714: FAQ
  • +AD7714YN: FAQ
  • +AD7715: FAQ
  • +AD7716: FAQ
  • +AD7718: FAQ
  • +AD7719: FAQ
  • +AD7720: FAQ
  • +AD7722: FAQ
  • +AD7725: FAQ
  • +AD7730: FAQ
  • +AD7731: FAQ
  • +AD7732: FAQ
  • +AD7738: FAQ
  • +AD7740: FAQ
  • +AD7741: FAQ
  • +AD7745: FAQ
  • +AD7746: FAQ
  • +AD7747: FAQ
  • +AD7760: FAQ
  • +AD7763: FAQ
  • +AD7766: FAQ
  • +AD7768: FAQ
  • +AD777x: FAQ
  • +AD7780: FAQ
  • +AD7785: FAQ
  • +AD7787: FAQ
  • +AD7788: FAQ
  • +AD7790: FAQ
  • +AD7792: FAQ
  • +AD7793: FAQ
  • +AD7794: FAQ
  • +AD7795: FAQ
  • +AD7798: FAQ
  • +AD7799: FAQ
  • +AD7805: FAQ
  • +AD7808: FAQ
  • +AD7809: FAQ
  • +AD780: FAQ
  • +AD7811: FAQ
  • +AD7812: FAQ
  • +AD7817: FAQ
  • +AD7819: FAQ
  • +AD7821: FAQ
  • +AD7825: FAQ
  • +AD7829: FAQ
  • +AD7835: FAQ
  • +AD7849: FAQ
  • +AD7851: FAQ
  • +AD7854: FAQ
  • +AD7856: FAQ
  • +AD7858: FAQ
  • +AD7859: FAQ
  • +AD7864: FAQ
  • +AD7865 : FAQ
  • +AD7872: FAQ
  • +AD7874: FAQ
  • +AD7879: FAQ
  • +AD7887: FAQ
  • +AD7888: FAQ
  • +AD7891-1: FAQ
  • +AD7891: FAQ
  • +AD7893-2: FAQ
  • +AD7895: FAQ
  • +AD7896: FAQ
  • +AD7899: FAQ
  • +AD7912: FAQ
  • +AD7921: FAQ
  • +AD7924: FAQ
  • +AD7927: FAQ
  • +AD7938: FAQ
  • +AD7942: FAQ
  • +AD7949: FAQ
  • +AD7960: FAQ
  • +AD7961: FAQ
  • +AD797: FAQ
  • +AD7980: FAQ
  • +AD7982: FAQ
  • +AD7984: FAQ
  • +AD7986: FAQ
  • +AD7988-1: FAQ
  • +AD7993: FAQ
  • +AD7994: FAQ
  • +AD7997: FAQ
  • +AD7998: FAQ
  • +ADA2200: FAQ
  • +ADAS1000: FAQ
  • +ADAS3022: FAQ
  • +ADAS3023: FAQ
  • +ADC: FAQ
  • +ADVFC32: FAQ
  • +EVAL-AD7719-EB: FAQ
  • +EVAL-ADAS3022EDZ: FAQ
  • +RDC1740: FAQ
  • +AD4116: FAQ
  • AD7398 SPI Voltage vs VCC
  • +DC590, DC2026, QuikEval: FAQs
  • +Legacy LTC - Sigma Delta ADCs FAQ
  • +Precision Technology Learning Modules
  • Programming FMC FRU ID EEPROM on Linux

AD7175-2 250kSPS, 24-bit Sigma Delta ADC

Q1. How do I interface to the ADC?

A1. The AD7175-2 uses an 3 or 4 wire SPI interface.

Q2. Can the part be used with CS tied low?

A2. Yes. However, using the AD7175-2 with CS tied low makes the interface less robust to interference and can cause loss of interface synchronization.

Q3. I’m not sure if my digital interface is working – how can I check this?

A3. The ADC has a read-only ID register which will always read back as 0x0CDx.

Q4. I don’t see a reset pin – how do you reset the ADC?

A4. The AD7175-2 does a power-on reset but can also be reset by writing 64 1’s to the part over the SPI interface.

Q5. Are there any precautions that should be taken to make the interface

more robust?

A5. The AD7175-2 has optional CRC protection for the interface so turning this on will make the interface more robust. Using CS will also make the interface more robust as when CS goes high the serial interface is set to a known state and any interference whilst CS is high will be ignored.

Q6. What does the MUX_IO bit do?

A6. The MUX_IO bit enables the AD7175-2 GPIOs as external multiplexer control lines. GPIO0 and GPIO1 will toggle in synchronization with the ADCs internal sequencer.

Q7. Is it possible to control the conversion start similar to using CONVST on a SAR ADC?

A7. Yes, the AD7175-2 has a SYNC input which can be used to control the conversion start.

Q8. There are a number of filter options – which one should I use?

A8. The AD7175-2 has three filter options; Sinc5+Sinc1, Sinc3 and enhanced 50 & 60 Hz filters. The Sinc5+Sinc1 is most suited to multichannel applications where fast multiplexing is required. The Sinc3 is best for single channel applications running at lower output data rates. In applications where rejection of 50 and 60 Hz is important the enhanced 50 & 60 Hz rejection filters should be used as they provide better performance that the Sinc filters and allow the user to trade off settling time or rejection to meet their application needs. We provide a  filter tool to help during  design in: see www.analog.com/AD7175-2

Q9. The AD7175-2 has a maximum output data rate of 250 kSPS but a channel scan rate of 50 kSPS / channel. What does this mean?

A9. When operating on a single channel the AD7175-2 can output data at up to 250 kSPS. However, when more than one channel is enabled the full filter settling time must be allowed for each channel. The data rate for fully settled data is 50 kSPS. So, if using 2 channels the output data rate for each channel is 50 kSPS / 2 which is 25 kSPS.

Q10. Can the ADC be configured to settle in a single cycle ?

A10. Yes, setting the SING_CYC bit will allow this. It should be noted that the Sinc5+Sinc1 filter will settle in a single cycle at output data rates of 10 kSPS and lower regardless of whether the SING_CYC bit is set or not.

Q11. The AD7175-2 has integrated truly rail to rail analog input and reference input buffers. What advantage do these have over normal RRIO buffers ?

A11. Normal rail to rail input/output (RRIO) buffers can often degrade in their linearity performance when they get close to the rail. The AD7175-2 buffers are truly rail to rail meaning that this degradation does not occur. In addition, these buffers are chopped and so have excellent offset performance and no 1/f noise profile.

  • sigma-delta
  • faq
  • ad7175-2
  • Share
  • History
  • More
  • Cancel
Related
Recommended
Social
Quick Links
  • About ADI
  • ADI Signals+
  • Analog Dialogue
  • Careers
  • Contact us
  • Investor Relations
  • News Room
  • Quality & Reliability
  • Sales & Distribution
  • Incubators
Languages
  • English
  • 简体中文
  • 日本語
Newsletter

Interested in the latest news and articles about ADI products, design tools, training and events? Subscribe today!

Sign Up
Analog Logo
©1995 - 2023 Analog Devices, Inc. All Rights Reserved
沪ICP备09046653号-1
  • Sitemap
  • Legal
  • Privacy & Security
  • Privacy Settings
EngineerZone Uses cookies to ensure you get the best experience in our community. For more information on cookies, please read our Privacy & Security Statement.