Analog.com Analog Dialogue Wiki 简体中文
EngineerZone
EngineerZone
  • Log In
  • Site
  • Search
  • User
  • Support

    Popular Forums

    • RF and Microwave
    • Power Management
    • Video
    • FPGA Reference Designs
    • Precision ADCs
    • Linux Software Drivers
    • SigmaDSP Processors & SigmaStudio Dev. Tool

    Product Forums

    • A2B
    • Amplifiers
    • Analog Microcontrollers
    • Clock and Timing
    • Data Converters
    • Direct Digital Synthesis (DDS)
    • Energy Monitoring and Metering
    • Interface and Isolation
    • MEMS Inertial Sensors
    • Processors and DSP
    • Switches/Multiplexers
    • Temperature Sensors
    • Voltage References
    View All

    Application Forums

    • Audio
    • Automated Test Equipment (ATE)
    • Condition-Based Monitoring
    • Depth, Perception & Ranging Technologies
    • Embedded Vision Sensing Library
    • Motor Control Hardware Platforms
    • Optical Sensing
    • Precision Technology Signal Chains Library
    • Video
    • Wireless Sensor Networks Reference Library

    Design Center Forums

    • ACE Evaluation Software
    • ADEF System Platforms
    • Design Tools and Calculators
    • FPGA Reference Designs
    • Linux Software Drivers
    • Microcontroller no-OS Drivers
    • Reference Designs
    • Signal Chain Power (SCP)
    • Software Interface Tools
    • System Demonstration Platform (SDP) Support
  • Learn

    Highlighted Webinar

    Robust Industrial Motor Encoder Signal Chain Solutions

    Recent Discussions

    • About the values of CurV1,2 displayed in the cursors frame of scopy.
    • Purpose of "Load" in Scopy signal generator configuration GUI
    • about the transient response experiment example of RL Circuit using adalm2000
    • Using ADALM1000 AIN and CHA as kelvin connection
    • I2C communication with ADALM2OOO Through Scopy

    Places

    • ADI Education Home
    • ADI Education China
    • ADI Education India
    • ADI Education Philippines
    • StudentZone (Analog Dialogue)
    • Virtual Classroom

    Latest Webinars

    • Robust Industrial Motor Encoder Signal Chain Solutions
    • Precision Low Power Measurement Solutions for Intelligent Edge
    • Advantages of Integrating Digital Power System Management (DPSM) into your Design
    • Optimizing GaN and GaAs RF Amplifier Performance Using Novel Biasing Techniques
    • Improving Switch-Mode Power Supplies Using Noise Cancelling Technology
    View All Webinars
  • Community Hub

    Challenge Yourself!

      KCC's Quizzes AQQ230 about a clock and angle puzzle
    View All

    Places

    • Community Help
    • Logic Lounge

    Resources

    • EZ Code of Conduct
    • Getting Started Guide
    • ADI: Words Matter
    • Community Help Videos
    View All
  • Blogs

    Highlighted Blogs

    Using Python To Control The Pluto Radio And Plot Data

     

    Resistance is NOT Futile

    Latest Blogs

    • What is The Continuity of Engineering?
    • Move Over Sensors: Actuators Are Entering The Smart Factory Stage
    • What To Call A Non-Compliant Item
    • How to Construct a Beamformer with the ADALM-PLUTO
    • Customize Your EZ Experience
    Read All Blogs

    ADI Blogs

    • EZ Spotlight
    • The Engineering Mind
  • Partners

    Electronic Design Services - PartnerZone

    • Boston Engineering
    • Calian, Advanced Technologies
    • Colorado Engineering Inc. (DBA CAES AT&E)
    • Clockworks Signal Processing
    • Epiq Solutions
    • Fidus
    • PalmSens
    • Richardson RFPD
    • Tri-Star Design, Inc.
    • VadaTech
    • Vanteon
    • X-Microwave
    View All
Precision ADCs
  • Data Converters
Precision ADCs
Documents Synchronization of multiple AD7175-2 + Set ODR to 20kSPS
  • Forums
  • File Uploads
  • FAQs/Docs
  • Members
  • Tags
  • More
  • Cancel
  • +Documents
  • +General: FAQ
  • +AD1139: FAQ
  • +AD1556: FAQ
  • +AD1580: FAQ
  • +AD1582: FAQ
  • +AD2S1200: FAQ
  • +AD2S1205: FAQ
  • +AD2S1210: FAQ
  • +AD2S75: FAQ
  • +AD2S80: FAQ
  • +AD2S80A: FAQ
  • +AD2S82A: FAQ
  • +AD2S83: FAQ
  • +AD2S90: FAQ
  • +AD2S99: FAQ
  • +AD4110-1: FAQ
  • +AD411x: FAQ
  • +AD5940: FAQ
  • +AD598: FAQ
  • +AD650: FAQ
  • +AD652: FAQ
  • +AD654: FAQ
  • +AD7091: FAQ
  • +AD7091r: FAQ
  • +AD711: FAQ
  • +AD7124-4: FAQ
  • +AD7124-8: FAQ
  • +AD7134: FAQ
  • +AD713: FAQ
  • +AD7142: FAQ
  • +AD7147: FAQ
  • +AD7148: FAQ
  • +AD7150: FAQ
  • +AD7151: FAQ
  • -AD7175-2: FAQ
    • There are a number of filter options for the AD7175-2 – which one should I use?
    • I don't see a RESET pin on the AD7175-2, How do I reset the ADC?
    • AD7175-2 digital interface check
    • Synchronization of multiple AD7175-2 + Set ODR to 20kSPS
    • The AD7175-2 has a maximum output data rate of 250 kSPS but a channel scan rate of
    • What does the MUX_IO bit do on the AD7175-2?
    • Are there any precautions that should be taken to make the interface for the AD7175-2 more robust?
    • AD7175-2 250kSPS, 24-bit Sigma Delta ADC
    • Can the AD7175-2 be configured to settle in a single cycle?
  • +AD7176-2: FAQ
  • +AD7176: FAQ
  • +AD717x: FAQ
  • +AD7190: FAQ
  • +AD7192: FAQ
  • +AD7193: FAQ
  • +AD7195: FAQ
  • +AD719x: FAQ
  • +AD7265: FAQ
  • +AD7266: FAQ
  • +AD7280: FAQ
  • +AD7291: FAQ
  • +AD7298: FAQ
  • +AD7305: FAQ
  • +AD7321: FAQ
  • +AD7323: FAQ
  • +AD7328: FAQ
  • +AD7366-5: FAQ
  • +AD7367: FAQ
  • +AD736ARZ: FAQ
  • +AD737: FAQ
  • +AD7380 : FAQ
  • +AD7398: FAQ
  • +AD7400A: FAQ
  • +AD7401: FAQ
  • +AD7403: FAQ
  • +AD74111: FAQ
  • +AD7415: FAQ
  • +AD7416: FAQ
  • +AD7417: FAQ
  • +AD7418: FAQ
  • +AD7450: FAQ
  • +AD7475: FAQ
  • +AD7484: FAQ
  • +AD7490: FAQ
  • +AD7492: FAQ
  • +AD75019: FAQ
  • +AD7503: FAQ
  • +AD7541A: FAQ
  • +AD7546: FAQ
  • +AD7547: FAQ
  • +AD7568: FAQ
  • +AD7578: FAQ
  • +AD7606-4: FAQ
  • +AD7606: FAQ
  • +AD7606B: FAQ
  • +AD7606C: FAQ
  • +AD7608: FAQ
  • +AD7616 FAQ
  • +AD7616-P: FAQ
  • +AD7621: FAQ
  • +AD7625: FAQ
  • +AD7626: FAQ
  • +AD7631: FAQ
  • +AD7653: FAQ
  • +AD7654: FAQ
  • +AD7655: FAQ
  • +AD7656: FAQ
  • +AD7657-1: FAQ
  • +AD7663: FAQ
  • +AD7674: FAQ
  • +AD7675: FAQ
  • +AD7678: FAQ
  • +AD7682: FAQ
  • +AD7683: FAQ
  • +AD7684: FAQ
  • +AD7685: FAQ
  • +AD7688: FAQ
  • +AD7689: FAQ
  • +AD7690: FAQ
  • +AD7691: FAQ
  • +AD7705: FAQ
  • +AD7706: FAQ
  • +AD7707: FAQ
  • +AD7708: FAQ
  • +AD7709: FAQ
  • +AD7710: FAQ
  • +AD7711A: FAQ
  • +AD7712: FAQ
  • +AD7713: FAQ
  • +AD7714: FAQ
  • +AD7714YN: FAQ
  • +AD7715: FAQ
  • +AD7716: FAQ
  • +AD7718: FAQ
  • +AD7719: FAQ
  • +AD7720: FAQ
  • +AD7722: FAQ
  • +AD7725: FAQ
  • +AD7730: FAQ
  • +AD7731: FAQ
  • +AD7732: FAQ
  • +AD7738: FAQ
  • +AD7740: FAQ
  • +AD7741: FAQ
  • +AD7745: FAQ
  • +AD7746: FAQ
  • +AD7747: FAQ
  • +AD7760: FAQ
  • +AD7763: FAQ
  • +AD7766: FAQ
  • +AD7768: FAQ
  • +AD777x: FAQ
  • +AD7780: FAQ
  • +AD7785: FAQ
  • +AD7787: FAQ
  • +AD7788: FAQ
  • +AD7790: FAQ
  • +AD7792: FAQ
  • +AD7793: FAQ
  • +AD7794: FAQ
  • +AD7795: FAQ
  • +AD7798: FAQ
  • +AD7799: FAQ
  • +AD7805: FAQ
  • +AD7808: FAQ
  • +AD7809: FAQ
  • +AD780: FAQ
  • +AD7811: FAQ
  • +AD7812: FAQ
  • +AD7817: FAQ
  • +AD7819: FAQ
  • +AD7821: FAQ
  • +AD7825: FAQ
  • +AD7829: FAQ
  • +AD7835: FAQ
  • +AD7849: FAQ
  • +AD7851: FAQ
  • +AD7854: FAQ
  • +AD7856: FAQ
  • +AD7858: FAQ
  • +AD7859: FAQ
  • +AD7864: FAQ
  • +AD7865 : FAQ
  • +AD7872: FAQ
  • +AD7874: FAQ
  • +AD7879: FAQ
  • +AD7887: FAQ
  • +AD7888: FAQ
  • +AD7891-1: FAQ
  • +AD7891: FAQ
  • +AD7893-2: FAQ
  • +AD7895: FAQ
  • +AD7896: FAQ
  • +AD7899: FAQ
  • +AD7912: FAQ
  • +AD7921: FAQ
  • +AD7924: FAQ
  • +AD7927: FAQ
  • +AD7938: FAQ
  • +AD7942: FAQ
  • +AD7949: FAQ
  • +AD7960: FAQ
  • +AD7961: FAQ
  • +AD797: FAQ
  • +AD7980: FAQ
  • +AD7982: FAQ
  • +AD7984: FAQ
  • +AD7986: FAQ
  • +AD7988-1: FAQ
  • +AD7993: FAQ
  • +AD7994: FAQ
  • +AD7997: FAQ
  • +AD7998: FAQ
  • +ADA2200: FAQ
  • +ADAS1000: FAQ
  • +ADAS3022: FAQ
  • +ADAS3023: FAQ
  • +ADC: FAQ
  • +ADVFC32: FAQ
  • +EVAL-AD7719-EB: FAQ
  • +EVAL-ADAS3022EDZ: FAQ
  • +RDC1740: FAQ
  • +AD4116: FAQ
  • AD7398 SPI Voltage vs VCC
  • +DC590, DC2026, QuikEval: FAQs
  • +Legacy LTC - Sigma Delta ADCs FAQ
  • +Precision Technology Learning Modules
  • Programming FMC FRU ID EEPROM on Linux

Synchronization of multiple AD7175-2 + Set ODR to 20kSPS

Q 

I have 4 AD7175-2 connected together to convert 4 analog signals. The output
datarate is different slightly for each ADC. So I have to synchronize these 4
ADCs for simulatanous sampling. I use continous read mode. When I do a sync
periodically the continous read mode is canceled . I have to sample data with
20kHz.

1. How can I keep synchronisation of these four ADCs? How can I set the ODR to
20kSPS?
2.I tried to use single conversion mode, but the maximum datarate was below
10kSa. Is it possible to increase the output data rate in single conversion
mode up to 20kSa?

 

A 

1. The output data rate can be decreased to 20kSPS by the following procedure:

i. Set the ADC output data rate to 25 kSPS.
ii. Set the ADC to continuous conversion mode. No need to use continuous read
mode.
iii. Use an external SYNC pulse running at 20 kSPS to control the sampling rate.
iv. Each ADC can use its internal clock as the ADCs are synchronised for every
sample.

In case you wouldn't like to provide the SYNC pulse but instead are going to
provide a shared clock you can adjust this clock speed down to make the output
data rate 20 kSPS, as you mentioned in your previous mail. While the lower
limit on an external clock is not specified in AD7175-2's datasheet, it is no
problem running the ADC significantly slower than 16 MHz. Our product engineers
did some testing at 2MHz for example.

2. Regarding the single conversion mode, you can run the part up to 50 kSPS in
single conversion mode although in reality there are delays with writing to the
part and startup etc. That means it is closer to 40 kSPS max. However, I would
not using single conversion mode for this application.
  • ad7175-2
  • Share
  • History
  • More
  • Cancel
Related
Recommended
Social
Quick Links
  • About ADI
  • ADI Signals+
  • Analog Dialogue
  • Careers
  • Contact us
  • Investor Relations
  • News Room
  • Quality & Reliability
  • Sales & Distribution
  • Incubators
Languages
  • English
  • 简体中文
  • 日本語
Newsletter

Interested in the latest news and articles about ADI products, design tools, training and events? Subscribe today!

Sign Up
Analog Logo
©1995 - 2023 Analog Devices, Inc. All Rights Reserved
沪ICP备09046653号-1
  • Sitemap
  • Legal
  • Privacy & Security
  • Privacy Settings
EngineerZone Uses cookies to ensure you get the best experience in our community. For more information on cookies, please read our Privacy & Security Statement.