Q
Can the ADC be configured to settle in a single cycle?
A
Yes, setting the SING_CYC bit will allow this. It should be noted that the
Sinc5+Sinc1 filter will settle in a single cycle at output data rates of 10
kSPS and lower regardless of whether the SING_CYC bit is set or not.