Search FAQs on the left to see if your question has been answered. Click on the dropdown to view all of the documents associated with the product. If you can't find your question, click on Ask a Question

ADA2200: ACE File format for importing filters FAQs

We recently got the following question from a customer.

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

I am using the following setup:

 

- ADA2200SDP-EVALZ  revision C

- EVAL-SDP-CB1Z  Revision 1.3

- ACE Software  Version 1.9.2639.1092

 

I’m trying to setup a Custom IIR Filter. The ACE software accepts a .txt file in the “IIR Coefficients File Path” section, at which I could place my own coefficients. But how does this file has to look like in terms of formatting and order? I could not find any information regarding this in the ADA2200 datasheet. I have also read the MT-234 file but it didn’t helped me either. Thank you in advance.

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

Reply:

The files are formatted as:

Reg#  value

 

Where,

Reg# - is the register number as a decimal value.

Value – is the decimal register value.

 

So, to place into register 0x0011 the value 0xC0.  The file would contain:

17  192

 

I have attached a file as an example.  This file contains the coefficients from BP1 explained in MT-234.

Comments
Anonymous