Article AD4030-40 and 1/f noise

Question: can you advise ADA4030-24, the 1/f noise and amplitude. 

 

Answer: The AD4030-24 1/f noise is cancelled internally by auto-zeroing. Noise spectral density is substantially uniform from dc to fS/2.