AD7745: FAQ

  • Created
  • Updated
Was this helpful?
  • AD7745/46/47 addressing for multiple slave devices on I2C bus

    Q I want to connect several Capacitance to Digital Converters (AD7745, AD7746, AD7747) using the I2C bus. The question is how can I get the slave address of each device or how can set the slave address…
  • AD7745: Capacitance Application

    Q 1.:What is the difference between the AD7745 and the AD7747? Is it only the different resolution and accuracy and the input range? 2.:What is the difference between the models for the AD7746: ARUZ…
  • Ad7745: Higher capacitive value

    Q Is it possible to extend the range of measured capacitances above 4 pF by decreasing excitation signal e.g. to a value of VDD/4 ? A 1) Connect a known fixed capacitor in series with the sensor…
  • AD7745: Higher input capacitance

    Q The datasheet states that the max. common-mode cap for a AD7745 is 17pF. Is it possible to connect 50pF? Maybe with a voltage devider at EXCx? A 1) Connect a known fixed capacitor in series with…
  • ad7745: Sensors with higher capacative range

    Q They make humidiysensors with a capacitive output. Therefor, they have interests in CDC as AD7745. But the nominal capacitance of their sensors is 180pF with a max. change of +-50pF, which is higher…
  • AD7745: Start a conversion in single conversion mode

    Q How to start a conversion in single conversion mode? A How to start a conversion in single conversion mode: It is the operation of writing "010" to the mode bits MD2-MD0 in the configuration…
  • AD7745: there is no input protection circuit

    Q Are there some protection circuit in front of the AD7745 to limit the input voltage and current while not affecting the capacitance measurement. A the AD7745 has no over voltage protection please…
  • Long Term Drift Bahavior

    Q What is the AD7745 long term drift behavior? A We guarantee accuracy within a 4fF band. In fact each part is factory tested to ensure that it is within a 2fF band; the extra 2fF then takes account…
  • The absolute maximum ratings for AD7745 state the following;

    Q The absolute maximum ratings for AD7745 state the following; I expect this device to be able to tolerate the Pb free solder temperature of 260C , Is AD7745 able to withstand up to 260C during Pb free…

Before You Switch


Switching languages will make ADI Explorer unavailable. Resume your session by switching back to English and reopening ADI Explorer.