Q
Can the AD9684 support DC coupled signals?
A
The AD9684 can support DC coupling if the common mode voltage is kept at the
recommended level. In DC-coupled applications, set the common-mode voltage to
2.05 V, ±100 mV to ensure proper ADC operation.