Q
Why would I use the device in 32-bit resolution mode if I can get 64 bits or resolution in programmable modulus mode?
A
Using programmable modulus mode requires the auxiliary accumulator, so…
Q
Are there conditions that will help the part reach its best performance?
A
Yes, if you can provide a digital power supply which holds to 1.8V+5%/-0%, and if you can keep the part cooled, you…
Q
Could you please send me the source code for the AD9914 Eval Board?
A
I do not believe the software source code is what your customer needs. Instead, I am sending you some of the code we used…
Q
looking for info wrt (a) on phase truncation spurs sampled data points mapped on to a 32-bit phase wheel lookup table. (b) synchronisation pins, SYNC_IN and SYNC_OUT.
A
Please note for technical…
Q
When using programmable modulus mode, is the tuning resolution listed the same no matter what sample frequency I use?
A
No. The absolute resolution is calculated as FSAM/2^64, though even that…
Q
How good is the AD9914/AD9915 REFCLK multiplier?
A
It’s better, at least a little, than those on previous DDS products, but it will still limit your performance compared to a very clean driven…
Q
Why is the AD9915 SFDR specification better than the AD9914?
A
Because as the sample rate increases, it is more challenging to hold to good SFDR. If you use the AD9914 at 2.5GHz or less, it will…
Q
Will these devices work in Super Nyquist zones?
A
Yes, as with other DDS products, you will likely want to use a bandpass filter if you plan to go Super Nyquist.
Q
Is the AD9914's EPAD internally connected to AGND or DGND?
A
The AGND pins are connected to the EPAD internally. If the EPAD is not externally connected to ground, the chip would still be functional…
Q
What will happen if I try to run the AD9914 faster than 3.5 GHz?
A
The device shouldn’t just crash, but you should expect to see phase noise and SFDR suffer as you press past the specified maximum…