Article If there is noise on the voltage supply to the MAX31855, should a low noise voltage regulator be implemented to reduce the temperature conversion error?

If there is significant noise on the supply to the MAX31855, you will experience some errors in the temperature conversion results, so implementing a voltage regulator on VCC would be advised.

As an example, when using a stable 3.3V supply, and the MAX31855 will read about 24.4C from the internal temperature sensor of the MAX31855. With a 240kHz 40mVpp signal applied to the 3.3V supply, a sine-wave form would induce a -2.2C error, and a square-wave form would induce a +10.5C error. The supply noise impacts the internal ADC, so this will also affect thermocouple conversion accuracy.  A separate, clean supply will be needed to ensure accurate temperature conversions.