<?xml-stylesheet type="text/xsl" href="https://ez.analog.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:slash="http://purl.org/rss/1.0/modules/slash/" xmlns:wfw="http://wellformedweb.org/CommentAPI/" xmlns:atom="http://www.w3.org/2005/Atom"><channel><title>Q&amp;amp;A - Recent Threads</title><link>https://ez.analog.com/condition-based-monitoring/f/q-a</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><lastBuildDate>Fri, 31 Oct 2025 10:47:56 GMT</lastBuildDate><atom:link rel="self" type="application/rss+xml" href="https://ez.analog.com/condition-based-monitoring/f/q-a" /><item><title>Voyager 4 - COM communication drops after continuous CSV data logging</title><link>https://ez.analog.com/thread/600508?ContentTypeID=0</link><pubDate>Fri, 31 Oct 2025 10:47:56 GMT</pubDate><guid isPermaLink="false">a884d118-f55f-49de-87eb-b9dbaf99b3e3:83b252b0-ae15-46c7-bda5-4b4a4c438693</guid><dc:creator>sandrac</dc:creator><slash:comments>0</slash:comments><comments>https://ez.analog.com/thread/600508?ContentTypeID=0</comments><wfw:commentRss>https://ez.analog.com/condition-based-monitoring/f/q-a/600508/voyager-4---com-communication-drops-after-continuous-csv-data-logging/rss?ContentTypeId=0</wfw:commentRss><description>&lt;p&gt;Hello,&lt;br /&gt;I&amp;rsquo;m using the Voyager 4 device for communication over USB. When I continuously collect and save data to .csv files, after some time the communication over the COM port stops responding.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;The issue looks like this:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;The program runs correctly for a while (data logging works fine).&lt;/li&gt;
&lt;li&gt;After some time, the COM communication drops.&lt;/li&gt;
&lt;li&gt;Reconnecting the USB cable restores communication, but my application terminates unexpectedly due to the COM port disconnect.&lt;/li&gt;
&lt;li&gt;I have tried using different USB cables and ports, but the issue still persists.&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;Has anyone else experienced this issue with Voyager 4 when continuously logging data over USB? Is there a known firmware update or workaround for maintaining stable COM communication over long sessions? Are there any recommended timeouts, buffer limits, or flow control settings for this device?&lt;br /&gt;Thank you in advance for your help.&lt;br /&gt;&lt;br /&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Strange behaviour of Accelerometer values in CN0549 Condition Based Monitoring-Platform</title><link>https://ez.analog.com/thread/595808?ContentTypeID=0</link><pubDate>Fri, 16 May 2025 12:44:40 GMT</pubDate><guid isPermaLink="false">a884d118-f55f-49de-87eb-b9dbaf99b3e3:970b8ca3-1a6b-4d7a-9ecd-492fcc437f4d</guid><dc:creator>RobWoody</dc:creator><slash:comments>0</slash:comments><comments>https://ez.analog.com/thread/595808?ContentTypeID=0</comments><wfw:commentRss>https://ez.analog.com/condition-based-monitoring/f/q-a/595808/strange-behaviour-of-accelerometer-values-in-cn0549-condition-based-monitoring-platform/rss?ContentTypeId=0</wfw:commentRss><description>&lt;p&gt;I got this setup &lt;a href="https://wiki.analog.com/resources/eval/user-guides/circuits-from-the-lab/cn0540/coraz7s"&gt;CN0540 and the CoraZ7-07s [Analog Devices Wiki]&lt;/a&gt;&amp;nbsp;getting to work.&amp;nbsp;&lt;span&gt;When i started with this setup, i first used the IIO Oscilloscope Software to get a quick view on the data/FFT because i was interested. I installed the App phyphox on my iPhone and generated a 2 kHz and a 4 kHz signal and held it next to the sensor. In the FFT i saw a peak at 2 and 4 kHz. So everything was looking fine. I then started to create a python script that gets the data from the sensor. I also got this to work.&lt;/span&gt;&amp;nbsp;The only problem I have is that I get strange values from the sensor. I leave the sensor on the table while measuring and read out the values. In my Python script I set the rx_output_type to &amp;ldquo;raw&amp;rdquo;. In my opinion, I should only get values in a constant area when the sensor is at rest. However, if I carry out measurements at two different times, I get different values. For example, one day the values fluctuate between -300 and -700, the next day the values suddenly fluctuate between -2158100 and -215600. I have no idea why the values vary so much although I have not changed anything in the hard- or software. Do you guys have any idea why the values are behaving like this or how to investigate on this? I then tried the IIO Oscilloscope again and to my surprise, i wasn&amp;#39;t able to recreate the 2 and 4 kHz example. When i hold the iPhone next to the sensor, i can&amp;#39;t see a peak anywhere. Why is that and could this have the same cause as the strange values?&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>LTM4644IY#PBF internal framework issues</title><link>https://ez.analog.com/thread/593060?ContentTypeID=0</link><pubDate>Fri, 28 Feb 2025 03:42:10 GMT</pubDate><guid isPermaLink="false">a884d118-f55f-49de-87eb-b9dbaf99b3e3:f7c49178-8237-4da4-8391-6682093e603a</guid><dc:creator>apple6868188</dc:creator><slash:comments>0</slash:comments><comments>https://ez.analog.com/thread/593060?ContentTypeID=0</comments><wfw:commentRss>https://ez.analog.com/condition-based-monitoring/f/q-a/593060/ltm4644iy-pbf-internal-framework-issues/rss?ContentTypeId=0</wfw:commentRss><description>&lt;p&gt;We have received your products many times, but the internal X-RAY sequence frames are different. For example, LTM4644IY#PBF is shown in the following figure. Please help us to see what causes this situation, thanks a lot.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;img style="max-height:240px;max-width:320px;" src="https://ez.analog.com/resized-image/__size/640x480/__key/communityserver-discussions-components-files/994/1.png" alt=" " /&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Saving multiple data records from CN0549 to memory (i.e. inserted SD-Card) or streaming data to python</title><link>https://ez.analog.com/thread/592262?ContentTypeID=0</link><pubDate>Thu, 06 Feb 2025 16:22:33 GMT</pubDate><guid isPermaLink="false">a884d118-f55f-49de-87eb-b9dbaf99b3e3:77a2ab82-86f9-425f-81d2-b15ee967153d</guid><dc:creator>RobWoody</dc:creator><slash:comments>0</slash:comments><comments>https://ez.analog.com/thread/592262?ContentTypeID=0</comments><wfw:commentRss>https://ez.analog.com/condition-based-monitoring/f/q-a/592262/saving-multiple-data-records-from-cn0549-to-memory-i-e-inserted-sd-card-or-streaming-data-to-python/rss?ContentTypeId=0</wfw:commentRss><description>&lt;p&gt;I bought the reference design CN0549 with the CoraZ7 board, CN0540 and the CN0532. I have the ADI IIO Oscilloscope software running on my Windows computer and can visualize the oscillation data. However, when I save the data, only a single data set is saved in the CSV file. How can I ensure that not just one but several data records are saved in the CSV file? Is this even possible or do I have to use additional software (Python, for example, as I don&amp;#39;t have Matlab) to access and save the data?&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Enabling Activity interupt</title><link>https://ez.analog.com/thread/587860?ContentTypeID=0</link><pubDate>Mon, 07 Oct 2024 13:34:40 GMT</pubDate><guid isPermaLink="false">a884d118-f55f-49de-87eb-b9dbaf99b3e3:b828b733-7292-4ee1-bc98-be89f70634a2</guid><dc:creator>AD11</dc:creator><slash:comments>0</slash:comments><comments>https://ez.analog.com/thread/587860?ContentTypeID=0</comments><wfw:commentRss>https://ez.analog.com/condition-based-monitoring/f/q-a/587860/enabling-activity-interupt/rss?ContentTypeId=0</wfw:commentRss><description>&lt;p&gt;Hello,&lt;br /&gt;I am trying to enable activity interrupt and i think i am having some issues:&lt;br /&gt;1- i think there has to be some ordering for registers as if i change ordering of registers i see settings are applied otherwise it&amp;#39;s not.&lt;br /&gt;2- Even after configuration taking effect and reading register and i can see activity interrupt is enable. I still don&amp;#39;t receive any interrupt from sensor on motion but when it&amp;#39;s not moving i can see some dummy interrupts triggered! No matter what threshold i use.&lt;/p&gt;
&lt;p&gt;3 - Is activity interrupt is enabled only in measurements mode? As i was looking forward to use it in low power mode.&lt;br /&gt;&lt;br /&gt;Thanks in advance&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Voyager 3 sensor board connector pinout ?</title><link>https://ez.analog.com/thread/583831?ContentTypeID=0</link><pubDate>Fri, 14 Jun 2024 13:28:36 GMT</pubDate><guid isPermaLink="false">a884d118-f55f-49de-87eb-b9dbaf99b3e3:8af9435a-bdad-4fc1-89ec-c597a1544484</guid><dc:creator>cambridgedev</dc:creator><slash:comments>1</slash:comments><comments>https://ez.analog.com/thread/583831?ContentTypeID=0</comments><wfw:commentRss>https://ez.analog.com/condition-based-monitoring/f/q-a/583831/voyager-3-sensor-board-connector-pinout/rss?ContentTypeId=0</wfw:commentRss><description>&lt;p&gt;Hi,&lt;/p&gt;
&lt;p&gt;I&amp;#39;m evaluating the ADXL356 in the Voyager module. I need to interface directly with the ADCs on the sensor board using the SPI port.&lt;/p&gt;
&lt;p&gt;Where can I find the pinout for the flex connector on the Voyager sensor board ?&lt;/p&gt;
&lt;p&gt;Thanks.&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Help streaming data from Cn0549 and Cora Z7 to Matlab.</title><link>https://ez.analog.com/thread/576163?ContentTypeID=0</link><pubDate>Fri, 15 Dec 2023 09:58:20 GMT</pubDate><guid isPermaLink="false">a884d118-f55f-49de-87eb-b9dbaf99b3e3:b48d0d68-81b1-47de-82a7-b8eedb498bc6</guid><dc:creator>Besim</dc:creator><slash:comments>5</slash:comments><comments>https://ez.analog.com/thread/576163?ContentTypeID=0</comments><wfw:commentRss>https://ez.analog.com/condition-based-monitoring/f/q-a/576163/help-streaming-data-from-cn0549-and-cora-z7-to-matlab/rss?ContentTypeId=0</wfw:commentRss><description>&lt;p&gt;Dear CbM community,&amp;nbsp;&lt;/p&gt;
&lt;p&gt;I&amp;#39;m trying to stream data from the Cn0549 and Cora Z7 to matlab, following the advice from&amp;nbsp;&lt;a id="" href="https://wiki.analog.com/resources/eval/user-guides/circuits-from-the-lab/cn0549/matlab_example,"&gt;https://wiki.analog.com/resources/eval/user-guides/circuits-from-the-lab/cn0549/matlab_example&lt;/a&gt;&amp;nbsp;, I&amp;#39;ve installed the libiio 0.25 .exe file from&amp;nbsp;&lt;a id="" href="https://github.com/analogdevicesinc/libiio/releases/tag/v0.25"&gt;https://github.com/analogdevicesinc/libiio/releases/tag/v0.25&lt;/a&gt;&amp;nbsp;(I don&amp;#39;t know if that is what is meant to be installed so advice would be much appreciated) but when I go to run the code provided from the first link on Matlab I get the following error&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Error using adi.CN0532&lt;br /&gt;Method &amp;#39;releaseChanBuffers&amp;#39; in class &amp;#39;adi.common.RxTx&amp;#39; uses different access&lt;br /&gt;permissions than its superclass &amp;#39;matlabshared.libiio.base&amp;#39;. Set &amp;#39;releaseChanBuffers&amp;#39;&lt;br /&gt;access list to match superclass access list.&lt;/p&gt;
&lt;p&gt;&lt;img style="max-height:240px;max-width:320px;" alt=" " src="https://ez.analog.com/resized-image/__size/640x480/__key/communityserver-discussions-components-files/994/1_2E00_.png" /&gt;&lt;/p&gt;
&lt;p&gt;I do apologise If I&amp;#39;ve become annoying with these questions, but I come from a mechanical engineering background and I am not very familiar with these types of problems.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;thanks in advance.&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Can't pull out the inet address of eth0; Cn0459 and Cora Z7</title><link>https://ez.analog.com/thread/575938?ContentTypeID=0</link><pubDate>Sun, 10 Dec 2023 00:51:45 GMT</pubDate><guid isPermaLink="false">a884d118-f55f-49de-87eb-b9dbaf99b3e3:a1acb6f1-11e3-4a20-b8b7-60278f78eeae</guid><dc:creator>Besim</dc:creator><slash:comments>0</slash:comments><comments>https://ez.analog.com/thread/575938?ContentTypeID=0</comments><wfw:commentRss>https://ez.analog.com/condition-based-monitoring/f/q-a/575938/can-t-pull-out-the-inet-address-of-eth0-cn0459-and-cora-z7/rss?ContentTypeId=0</wfw:commentRss><description>&lt;p&gt;Hello everyone, I am trying to connect with my CN0540 and Cora Z7 as described in the guide (&lt;a id="" href="https://wiki.analog.com/resources/eval/user-guides/circuits-from-the-lab/cn0540/coraz7s"&gt;https://wiki.analog.com/resources/eval/user-guides/circuits-from-the-lab/cn0540/coraz7s&lt;/a&gt;); but when I open a session and write&amp;nbsp;&lt;strong&gt;ifconfig&lt;/strong&gt; in the terminal in order to get the device ip, I don&amp;#39;t get an ip as described on the guide, see attached image.&amp;nbsp; Thanks in advance.&lt;/p&gt;
&lt;p&gt;p.s. Sorry if the question is not worded correctly, English is not my first language&lt;/p&gt;
&lt;p&gt;&lt;img style="max-height:240px;max-width:1000px;" alt=" " src="https://ez.analog.com/resized-image/__size/2000x480/__key/communityserver-discussions-components-files/994/question.png" /&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Reading time domain data from CN 0540 through an arduino?</title><link>https://ez.analog.com/thread/571278?ContentTypeID=0</link><pubDate>Sat, 01 Jul 2023 14:53:49 GMT</pubDate><guid isPermaLink="false">a884d118-f55f-49de-87eb-b9dbaf99b3e3:b7fa7f76-848d-4dc3-bd0b-eb6766f59740</guid><dc:creator>Besim</dc:creator><slash:comments>1</slash:comments><comments>https://ez.analog.com/thread/571278?ContentTypeID=0</comments><wfw:commentRss>https://ez.analog.com/condition-based-monitoring/f/q-a/571278/reading-time-domain-data-from-cn-0540-through-an-arduino/rss?ContentTypeId=0</wfw:commentRss><description>&lt;p&gt;Dear&amp;nbsp;CbM Group,&lt;/p&gt;
&lt;p&gt;Recently I acquired two EVAL CN0540 ARDZ Shields and two EVAL CN0532 EBZ sensors, for a predictive maintenance project I&amp;#39;m working on, seeing that I have a couple of Arduino Unos Lying around can I use them to read data form the DAQ shield, so from which arduino pin can I read time domain unprocessed data ( processing to be done later in Matlab&amp;#39;s&amp;nbsp;diagnostic feature designer App), and how do I need to configure the other pins to provide the required info from arduino to the&amp;nbsp;DAQ shield.&lt;/p&gt;
&lt;p&gt;Any book or video recommendation that can help me solve this problem would be greatly appreciated.&lt;/p&gt;
&lt;p&gt;With respect,&amp;nbsp;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>CN0549</title><link>https://ez.analog.com/thread/570352?ContentTypeID=0</link><pubDate>Wed, 31 May 2023 00:08:57 GMT</pubDate><guid isPermaLink="false">a884d118-f55f-49de-87eb-b9dbaf99b3e3:295f9d42-98db-4c85-a1b9-d88769f45bd8</guid><dc:creator>Besim</dc:creator><slash:comments>3</slash:comments><comments>https://ez.analog.com/thread/570352?ContentTypeID=0</comments><wfw:commentRss>https://ez.analog.com/condition-based-monitoring/f/q-a/570352/cn0549/rss?ContentTypeId=0</wfw:commentRss><description>&lt;p&gt;Dear&amp;nbsp;CbM Group,&lt;/p&gt;
&lt;p&gt;I&amp;#39;m writing to you to enquire about the CN0549 Condition-Based Monitoring Development Platform, I&amp;#39;m a student and for my masters thesis I&amp;#39;m trying to do something about Predictive Maintenance using the CN0549 Condition-Based Monitoring Development Platform.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Seeing that I only want the CN0549 board to record data, and then use software like Matlab to process the data,&lt;/p&gt;
&lt;p&gt;My question is: Do I need to also buy the&amp;nbsp;DE10-Nano FPGA Board or can I connect the Data Acquisition Board directly to my PC.&lt;/p&gt;
&lt;p&gt;With Respect,&amp;nbsp;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Digital Measuring Tools</title><link>https://ez.analog.com/thread/569582?ContentTypeID=0</link><pubDate>Wed, 03 May 2023 05:07:36 GMT</pubDate><guid isPermaLink="false">a884d118-f55f-49de-87eb-b9dbaf99b3e3:b63aafc5-86bb-4977-8436-74bf1868608a</guid><dc:creator>ADIApproved</dc:creator><slash:comments>1</slash:comments><comments>https://ez.analog.com/thread/569582?ContentTypeID=0</comments><wfw:commentRss>https://ez.analog.com/condition-based-monitoring/f/q-a/569582/digital-measuring-tools/rss?ContentTypeId=0</wfw:commentRss><description>&lt;p&gt;Hello, I would like to inquire if Analog Devices has digital measuring devices that can measure the following:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;Airflow rate&lt;/li&gt;
&lt;li&gt;Static pressure&lt;/li&gt;
&lt;li&gt;Dry and wet temperature&lt;/li&gt;
&lt;li&gt;Relative humidity&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;It does not need to be only 1 product for&amp;nbsp;all parameters.&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Read the output of both EVAL-ADAF1080-3EBZ and CN0532</title><link>https://ez.analog.com/thread/568759?ContentTypeID=0</link><pubDate>Tue, 04 Apr 2023 01:58:30 GMT</pubDate><guid isPermaLink="false">a884d118-f55f-49de-87eb-b9dbaf99b3e3:e8afd6f3-5e71-4773-8458-640f2a75aaf7</guid><dc:creator>zhang132</dc:creator><slash:comments>1</slash:comments><comments>https://ez.analog.com/thread/568759?ContentTypeID=0</comments><wfw:commentRss>https://ez.analog.com/condition-based-monitoring/f/q-a/568759/read-the-output-of-both-eval-adaf1080-3ebz-and-cn0532/rss?ContentTypeId=0</wfw:commentRss><description>&lt;p&gt;To whom it may concerned,&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;I am trying to do some stuff about motor condition monitoring with both CN0549 as well as EVAL-ADAF1080-3EBZ.&lt;/p&gt;
&lt;p&gt;I have already get the FFT result of the&amp;nbsp;&lt;span&gt;EVAL-CN0532-EBZ on my PC by python with the tutortial&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span&gt;(&lt;a href="https://wiki.analog.com/resources/eval/user-guides/circuits-from-the-lab/cn0549/python_example"&gt;Streaming Data from the CN0549 into Python Tools [Analog Devices Wiki]&lt;/a&gt;)&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span&gt;and the hardware is set up as (&lt;a href="https://wiki.analog.com/resources/eval/user-guides/circuits-from-the-lab/cn0549"&gt;CN0549 User Guide [Analog Devices Wiki]&lt;/a&gt;)&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span&gt;, however, I would also like to get the value of the current sensor at the same time.&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span&gt;I think i can just connect the Vout pin of the&amp;nbsp;EVAL-ADAF1080-3EBZ to the DE10-Nano Analog input pin,&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span&gt;but I found out that the adi library does not support the ADAF1080, and I am wondering how could i solve this.&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span&gt;Thanks.&lt;/span&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>CN0540 + Arduino Or CN0540 + DE10-Nano FPGA, what should I use ?</title><link>https://ez.analog.com/thread/567627?ContentTypeID=0</link><pubDate>Mon, 27 Feb 2023 10:28:15 GMT</pubDate><guid isPermaLink="false">a884d118-f55f-49de-87eb-b9dbaf99b3e3:1ec9d72d-3806-4e25-b171-1f813afa18d7</guid><dc:creator>JAAFARA1M</dc:creator><slash:comments>4</slash:comments><comments>https://ez.analog.com/thread/567627?ContentTypeID=0</comments><wfw:commentRss>https://ez.analog.com/condition-based-monitoring/f/q-a/567627/cn0540-arduino-or-cn0540-de10-nano-fpga-what-should-i-use/rss?ContentTypeId=0</wfw:commentRss><description>&lt;p&gt;Hello everyone,&amp;nbsp;&lt;/p&gt;
&lt;p&gt;I bought your product, the EVAL-CN0540-ARDZ,&lt;img alt="CN0540 + Arduino Uno" src="https://ez.analog.com/resized-image/__size/640x480/__key/communityserver-discussions-components-files/994/0284.jpg" /&gt;&lt;span&gt;&amp;nbsp;&lt;/span&gt;and I saw on your website&amp;nbsp; &amp;quot;&amp;nbsp;&lt;a id="" href="https://wiki.analog.com/resources/eval/user-guides/circuits-from-the-lab/cn0540"&gt;https://wiki.analog.com/resources/eval/user-guides/circuits-from-the-lab/cn0540&lt;/a&gt;&lt;span&gt;&amp;nbsp;&lt;/span&gt;&amp;quot;that this card ( CN0540 ) can be powered by an Arduino Uno and&amp;nbsp; I&amp;#39;ve tried so long time to communicate between the two&amp;nbsp; but&amp;nbsp;I didn&amp;rsquo;t get any results,&amp;nbsp;on the other hand, I see that you&amp;#39;ve linked a device driver&amp;nbsp;&lt;img alt="Device driver" src="https://ez.analog.com/resized-image/__size/640x480/__key/communityserver-discussions-components-files/994/ask.JPG" /&gt;&amp;nbsp; which is for the ADC &amp;quot; AD7768-1 &amp;quot;,&lt;span&gt;&lt;strong&gt;Linux&lt;/strong&gt;&amp;nbsp;&lt;/span&gt;driver, so now I am wondering how can I use this driver and I am using an Arduino ???&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Again, on your website you mentioned&amp;nbsp;&lt;/p&gt;
&lt;h2 id="software_projects_and_platforms" class="sectionedit24"&gt;&lt;a id="Software_Projects_and_Platforms" name="Software_Projects_and_Platforms"&gt;&lt;/a&gt;Software Projects and Platforms&lt;/h2&gt;
&lt;ul&gt;
&lt;li class="level1"&gt;
&lt;div class="li"&gt;&lt;a class="wikilink1" title="resources:eval:user-guides:circuits-from-the-lab:cn0540:de10-nano" href="https://wiki.analog.com/resources/eval/user-guides/circuits-from-the-lab/cn0540/de10-nano"&gt;CN0540 + DE10-Nano FPGA&lt;/a&gt;&lt;/div&gt;
&lt;/li&gt;
&lt;li class="level1"&gt;
&lt;div class="li"&gt;&lt;a class="wikilink1" title="resources:eval:user-guides:circuits-from-the-lab:cn0540:coraz7s" href="https://wiki.analog.com/resources/eval/user-guides/circuits-from-the-lab/cn0540/coraz7s"&gt;CN0540 + Cora Z7s FPGA&lt;/a&gt;&lt;/div&gt;
&lt;/li&gt;
&lt;li class="level1"&gt;
&lt;div class="li"&gt;&lt;a class="wikilink1" title="resources:eval:user-guides:circuits-from-the-lab:cn0540:sdp-k1" href="https://wiki.analog.com/resources/eval/user-guides/circuits-from-the-lab/cn0540/sdp-k1"&gt;CN0540 + SDP-K1&lt;/a&gt;&lt;/div&gt;
&lt;/li&gt;
&lt;li class="level1"&gt;
&lt;div class="li"&gt;&lt;a class="wikilink1" title="resources:eval:user-guides:circuits-from-the-lab:cn0540:stm-discovery" href="https://wiki.analog.com/resources/eval/user-guides/circuits-from-the-lab/cn0540/stm-discovery"&gt;CN0540 + STM Discovery Kit&lt;/a&gt;&amp;nbsp;,&lt;/div&gt;
&lt;div class="li"&gt;&lt;/div&gt;
&lt;div class="li"&gt;&lt;/div&gt;
&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;but you didn&amp;#39;t give an example for using an Arduino with the CN0540, or any Arduino code to communicate between the CN0540 and the Arduino ????&lt;/p&gt;
&lt;p&gt;So, should I forget about using an Arduino and get a DE10-Nano FPGA or what ?&lt;/p&gt;
&lt;p&gt;Please I am waiting for your answer, Thank you.&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>CN0532 long term operating temperature</title><link>https://ez.analog.com/thread/567176?ContentTypeID=0</link><pubDate>Tue, 14 Feb 2023 02:35:05 GMT</pubDate><guid isPermaLink="false">a884d118-f55f-49de-87eb-b9dbaf99b3e3:afd5c0fa-4a72-43e9-8396-e6afcec54b1c</guid><dc:creator>FelipeCook</dc:creator><slash:comments>2</slash:comments><comments>https://ez.analog.com/thread/567176?ContentTypeID=0</comments><wfw:commentRss>https://ez.analog.com/condition-based-monitoring/f/q-a/567176/cn0532-long-term-operating-temperature/rss?ContentTypeId=0</wfw:commentRss><description>&lt;p&gt;Hi,&amp;nbsp;&lt;/p&gt;
&lt;div&gt;One of the equipment for which we want to monitor vibration has a surface temperature of 90 to 110 degree Celsius. These conditions are during 10 hour shifts, 6 days a week.&lt;/div&gt;
&lt;div&gt;&lt;/div&gt;
&lt;div&gt;Is the CN0532 capable for the job? The datasheet says maximum operating temperature 125 degrees, but it doesn&amp;#39;t&amp;nbsp;say anything about long term reliability at high temperatures.&lt;/div&gt;
&lt;p&gt;Regards,&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>What device that is used to connect the industrial accelerometer to computer?</title><link>https://ez.analog.com/thread/566582?ContentTypeID=0</link><pubDate>Tue, 24 Jan 2023 17:07:51 GMT</pubDate><guid isPermaLink="false">a884d118-f55f-49de-87eb-b9dbaf99b3e3:78e4a202-15c9-4bd1-9618-2bfa505824ad</guid><dc:creator>Noodleaddict77</dc:creator><slash:comments>3</slash:comments><comments>https://ez.analog.com/thread/566582?ContentTypeID=0</comments><wfw:commentRss>https://ez.analog.com/condition-based-monitoring/f/q-a/566582/what-device-that-is-used-to-connect-the-industrial-accelerometer-to-computer/rss?ContentTypeId=0</wfw:commentRss><description>&lt;p&gt;Hello everyone,&lt;/p&gt;
&lt;p&gt;I am quite new using accelerometer. I would like to get the signal from industrial MEMS accelerometer (1-axis) and do the signal analysis in my pc.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;I know only that I can connect ADXL345 accelerometer to arduino board, then connect to pc. However, for industrial accelerometer is quite different.&lt;/p&gt;
&lt;p&gt;I am not sure which device I have to interface with accelerometer before connecting to my pc.&lt;/p&gt;
&lt;p&gt;I would be appreciate if someone can help me out.&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;Thank you!&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Can I use ADXL345 to measure vibration of machine structure?</title><link>https://ez.analog.com/thread/566062?ContentTypeID=0</link><pubDate>Thu, 05 Jan 2023 18:19:01 GMT</pubDate><guid isPermaLink="false">a884d118-f55f-49de-87eb-b9dbaf99b3e3:234de2c0-c83b-477e-9cef-b64f5bb91295</guid><dc:creator>Noodleaddict77</dc:creator><slash:comments>1</slash:comments><comments>https://ez.analog.com/thread/566062?ContentTypeID=0</comments><wfw:commentRss>https://ez.analog.com/condition-based-monitoring/f/q-a/566062/can-i-use-adxl345-to-measure-vibration-of-machine-structure/rss?ContentTypeId=0</wfw:commentRss><description>&lt;p&gt;Hello everyone,&lt;/p&gt;
&lt;p&gt;I am quite new here. I would like to know if I can use accelerometer ADXL345 to measure the vibration of conveyor?&amp;nbsp;The maximum range of ADXL345 is +/-16g which I am not sure if it would be enough to measure the vibration.&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Maximizing vibration data sampling rate from ADXL357 for condition monitoring application</title><link>https://ez.analog.com/thread/560904?ContentTypeID=0</link><pubDate>Wed, 20 Jul 2022 12:43:52 GMT</pubDate><guid isPermaLink="false">a884d118-f55f-49de-87eb-b9dbaf99b3e3:84fca419-c5cd-432c-841b-416c2388b280</guid><dc:creator>Parminder</dc:creator><slash:comments>7</slash:comments><comments>https://ez.analog.com/thread/560904?ContentTypeID=0</comments><wfw:commentRss>https://ez.analog.com/condition-based-monitoring/f/q-a/560904/maximizing-vibration-data-sampling-rate-from-adxl357-for-condition-monitoring-application/rss?ContentTypeId=0</wfw:commentRss><description>&lt;p&gt;Hi there !!&lt;/p&gt;
&lt;p&gt;I am building a vibration monitoring application using ADXL357 with esp32 microcontroller. As per the information provided in cbm setup guide by ADI the number of datapoints collected in a second should be 5khz for 2.4 khz bandwidth.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;I have set the&amp;nbsp;ODR_LPF at 2000 Hz and 500 Hz and&amp;nbsp;HPF_CORNER at&amp;nbsp;6.2084 &amp;times; 10&amp;minus;4 &amp;times; ODR. and esp32 baud rate at 115200 through I2C.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Problem:&lt;/p&gt;
&lt;p&gt;I am getting 350 - 410 samples of vibration data in a second when I run a count to calculate the no of samples/sec.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Question&amp;nbsp;&lt;/p&gt;
&lt;p&gt;How can I get 5000 data samples/ sec ?&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Is my way of measuring the sampling data rate using a counter correct?&lt;/p&gt;
&lt;p&gt;Kindly provide me some guidance in the right direction.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Thanks.&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>ADXL326 frequency response drop seriously</title><link>https://ez.analog.com/thread/559711?ContentTypeID=0</link><pubDate>Thu, 16 Jun 2022 06:14:31 GMT</pubDate><guid isPermaLink="false">a884d118-f55f-49de-87eb-b9dbaf99b3e3:209eaeab-f2e1-43a2-909c-094c60417d7f</guid><dc:creator>fen1985</dc:creator><slash:comments>1</slash:comments><comments>https://ez.analog.com/thread/559711?ContentTypeID=0</comments><wfw:commentRss>https://ez.analog.com/condition-based-monitoring/f/q-a/559711/adxl326-frequency-response-drop-seriously/rss?ContentTypeId=0</wfw:commentRss><description>&lt;p&gt;Hi ADI guys，&lt;/p&gt;
&lt;p&gt;&amp;nbsp; We test ADXL326 recently as our new project application for low-frequency vibration ，and find there is some&amp;nbsp; frequency response problem，&lt;/p&gt;
&lt;p&gt;&amp;nbsp; We test X axis ,when the frequency&amp;nbsp; exceed 500HZ, the acceleration magnitude drop seriously, as below:&lt;em&gt;&lt;span class="skip"&gt;&lt;/span&gt;&lt;/em&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp; &amp;nbsp;&amp;nbsp;&lt;/p&gt;
&lt;table width="246"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td width="111"&gt;frequency(Hz)&lt;/td&gt;
&lt;td width="135"&gt;&amp;nbsp; Acceleration&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;50&lt;/td&gt;
&lt;td&gt;130&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;100&lt;/td&gt;
&lt;td&gt;130&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;400&lt;/td&gt;
&lt;td&gt;130&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;700&lt;/td&gt;
&lt;td&gt;118&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;1000&lt;/td&gt;
&lt;td&gt;2.8&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;1300&lt;/td&gt;
&lt;td&gt;2.46&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;&amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp;The actual bandwidth is much lower than 1.6KHz from the spec,How can we improve the ADXL326 BW? We set the&amp;nbsp; the Cout of the RC filter about 3nf .&lt;/p&gt;
&lt;p&gt;&amp;nbsp; &amp;nbsp; &amp;nbsp;Thanks a lot!&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Can anyone suggest similar features MEMS sensor for the attached conventional accelerometer datasheet?</title><link>https://ez.analog.com/thread/557734?ContentTypeID=0</link><pubDate>Mon, 25 Apr 2022 13:01:17 GMT</pubDate><guid isPermaLink="false">a884d118-f55f-49de-87eb-b9dbaf99b3e3:ba5df421-b936-4886-b61f-01b0fd0d35ad</guid><dc:creator>settisuresh</dc:creator><slash:comments>2</slash:comments><comments>https://ez.analog.com/thread/557734?ContentTypeID=0</comments><wfw:commentRss>https://ez.analog.com/condition-based-monitoring/f/q-a/557734/can-anyone-suggest-similar-features-mems-sensor-for-the-attached-conventional-accelerometer-datasheet/rss?ContentTypeId=0</wfw:commentRss><description>&lt;p&gt;&lt;a href="https://ez.analog.com/cfs-file/__key/communityserver-discussions-components-files/994/Type-8765A250M5_5F00_datasheet.pdf"&gt;ez.analog.com/.../Type-8765A250M5_5F00_datasheet.pdf&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;could you please suggest a MEMS sensor accelerometer, where the features are similar to the attached surface mount conventional accelerometer? Any type of suggestions are appreciated&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Thanking you!&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>How to convert Accelerometer data from ADXL375 into Velocity for condition monitoring?</title><link>https://ez.analog.com/thread/556643?ContentTypeID=0</link><pubDate>Sat, 26 Mar 2022 06:01:47 GMT</pubDate><guid isPermaLink="false">a884d118-f55f-49de-87eb-b9dbaf99b3e3:5c5f11c4-9165-4ca4-8411-173281145e8c</guid><dc:creator>shreeneet</dc:creator><slash:comments>1</slash:comments><comments>https://ez.analog.com/thread/556643?ContentTypeID=0</comments><wfw:commentRss>https://ez.analog.com/condition-based-monitoring/f/q-a/556643/how-to-convert-accelerometer-data-from-adxl375-into-velocity-for-condition-monitoring/rss?ContentTypeId=0</wfw:commentRss><description>&lt;p&gt;We are building a 0 to 1600Hz Bandwidth Vibration signal analysis system using ADXL372, ADXL375 &amp;amp; ADXL 357 based on budget. We will perform FFT of these values on dsPIC33xx&lt;/p&gt;
&lt;p&gt;Our frequency of interest is 30Hz to 240Hz, and would like to know if:&lt;/p&gt;
&lt;ol&gt;
&lt;li&gt;We should monitor Velocity instead of Acceleration for these frequency range&lt;/li&gt;
&lt;li&gt;How do we convert the acceleration data into reliable velocity data at Sampling rates of more than 6400 samples per axis?&lt;/li&gt;
&lt;li&gt;Any suggestions/guides&amp;nbsp;for onboard FFT on dsPIC33 (100MIPS) MCU with 32kb SRAM&lt;/li&gt;
&lt;li&gt;Any resource for us to gain more insights on above two points would be&amp;nbsp;helpful&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;All the inputs appreciated! Thank you in advance.&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>ADXl345 - number of Samples for ODR - 3200</title><link>https://ez.analog.com/thread/553781?ContentTypeID=0</link><pubDate>Fri, 07 Jan 2022 11:12:40 GMT</pubDate><guid isPermaLink="false">a884d118-f55f-49de-87eb-b9dbaf99b3e3:b9267212-09a1-4228-91b9-3d51d993f643</guid><dc:creator>Dig_acc</dc:creator><slash:comments>2</slash:comments><comments>https://ez.analog.com/thread/553781?ContentTypeID=0</comments><wfw:commentRss>https://ez.analog.com/condition-based-monitoring/f/q-a/553781/adxl345---number-of-samples-for-odr---3200/rss?ContentTypeId=0</wfw:commentRss><description>&lt;p&gt;Dear Sir/Madam,&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;p&gt;This is Srinivasa Rao Beera , working with Akrivia Automation. We are working on motor health monitoring project and we have selected ADXL345 . We are using 3200 Hz as output data rate. When we monitor output data samples from adxl345 , it is not exactly nearby 3200 number of samples.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;For example if we take 3 Nos adxl345 sensors, all three are not giving same number of samples .&amp;nbsp;&lt;/p&gt;
&lt;p&gt;First sensor is giving 3180 samples&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Second sensor is giving 3260 samples&amp;nbsp;&lt;/p&gt;
&lt;p&gt;Third sensor is giving 3300 samples.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;How can we get all sensors are in same page ?&amp;nbsp; Atleast&amp;nbsp;3200 samples +/- 5 samples in all the sensors. We have purchased 300 Nos sensor , so please help in this regard.&amp;nbsp;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>ADcmXL3021 RTS Mode status field</title><link>https://ez.analog.com/thread/551581?ContentTypeID=0</link><pubDate>Fri, 05 Nov 2021 10:08:40 GMT</pubDate><guid isPermaLink="false">a884d118-f55f-49de-87eb-b9dbaf99b3e3:58bf2ea9-8d8c-4cca-b0af-631c52e0e628</guid><dc:creator>rtstasur925</dc:creator><slash:comments>1</slash:comments><comments>https://ez.analog.com/thread/551581?ContentTypeID=0</comments><wfw:commentRss>https://ez.analog.com/condition-based-monitoring/f/q-a/551581/adcmxl3021-rts-mode-status-field/rss?ContentTypeId=0</wfw:commentRss><description>&lt;p&gt;Hello,&lt;/p&gt;
&lt;p&gt;I would like to know what the Status field each bit represent when the ADcmXL3021 is set to RTS Mode.&lt;br /&gt;because I didn&amp;#39;t notice any discribtions about this subject in the datasheet.&lt;br /&gt;PS.My ADcmXL3021 Date Codes is 1937.&lt;/p&gt;
&lt;p&gt;&lt;img style="max-height:240px;max-width:320px;" src="https://ez.analog.com/resized-image/__size/640x480/__key/communityserver-discussions-components-files/994/pastedimage1636135340361v1.png" alt=" " /&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>How to get the frequency to calculate the vibration value</title><link>https://ez.analog.com/thread/550569?ContentTypeID=0</link><pubDate>Sat, 09 Oct 2021 06:26:39 GMT</pubDate><guid isPermaLink="false">a884d118-f55f-49de-87eb-b9dbaf99b3e3:7b26f45d-94be-418f-a7f5-5b4d3f8cab9e</guid><dc:creator>sng.jarvis</dc:creator><slash:comments>1</slash:comments><comments>https://ez.analog.com/thread/550569?ContentTypeID=0</comments><wfw:commentRss>https://ez.analog.com/condition-based-monitoring/f/q-a/550569/how-to-get-the-frequency-to-calculate-the-vibration-value/rss?ContentTypeId=0</wfw:commentRss><description>&lt;p&gt;Dear All,&lt;/p&gt;
&lt;p&gt;I have the following queries to develop the MEMS Accelerometer to measure the vibration value in velocity (mm/sec)&lt;/p&gt;
&lt;p&gt;1.&amp;nbsp;If i am using ADXL335 or ADXL1002 means whether the frequency signal can be calculated by the sensor itself or external frequency needs to be given?&lt;/p&gt;
&lt;p&gt;2. If the frequency signal needs to be given externally then how to interface the signal with these sensors?&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>Failed to update Load Kernel Modules: Conditional based monitoring (CN0549</title><link>https://ez.analog.com/thread/550292?ContentTypeID=0</link><pubDate>Fri, 01 Oct 2021 12:45:48 GMT</pubDate><guid isPermaLink="false">a884d118-f55f-49de-87eb-b9dbaf99b3e3:ee21d1f8-2639-452e-9758-e5154bca9d79</guid><dc:creator>PreethamJayaram</dc:creator><slash:comments>1</slash:comments><comments>https://ez.analog.com/thread/550292?ContentTypeID=0</comments><wfw:commentRss>https://ez.analog.com/condition-based-monitoring/f/q-a/550292/failed-to-update-load-kernel-modules-conditional-based-monitoring-cn0549/rss?ContentTypeId=0</wfw:commentRss><description>&lt;p&gt;Hello, I&amp;nbsp;am using CN0549 conditional based monitoring platform with the CoraZ7-07s board. I&amp;rsquo;ve been having issues with booting ADI Kuiper Image on to the system.&lt;/p&gt;
&lt;p&gt;I have been getting errors&amp;nbsp;like&amp;nbsp;&lt;strong&gt;&amp;ldquo;Failed to update Load Kernel Modules&amp;rdquo;.&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;I&amp;rsquo;ve been following the procedure and softwares provided by Analog devices official user guide for the CBM platform (The link below).&lt;/p&gt;
&lt;p&gt;&lt;a title="CNO549 user guide" href="https://wiki.analog.com/resources/eval/user-guides/circuits-from-the-lab/cn0540/coraz7s"&gt;https://wiki.analog.com/resources/eval/user-guides/circuits-from-the-lab/cn0540/coraz7s&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;I even tried with the older versions of image from ADI but had the same issue. &lt;strong&gt;Please let me know what can be done to get over this issue&lt;/strong&gt;.&lt;/p&gt;
&lt;p&gt;The screenshot of the error&amp;nbsp;during the&amp;nbsp;boot sequence is attached below.&lt;/p&gt;
&lt;p&gt;Thank you.&lt;/p&gt;
&lt;p&gt;&lt;img style="max-height:240px;max-width:320px;" src="https://ez.analog.com/resized-image/__size/640x480/__key/communityserver-discussions-components-files/994/CN0549_5F00_error.jpeg" alt=" " /&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item><item><title>CN0549</title><link>https://ez.analog.com/thread/550071?ContentTypeID=0</link><pubDate>Mon, 27 Sep 2021 09:34:30 GMT</pubDate><guid isPermaLink="false">a884d118-f55f-49de-87eb-b9dbaf99b3e3:133f6451-1e0c-4843-ab5e-ca87d79db905</guid><dc:creator>NKokubo131</dc:creator><slash:comments>1</slash:comments><comments>https://ez.analog.com/thread/550071?ContentTypeID=0</comments><wfw:commentRss>https://ez.analog.com/condition-based-monitoring/f/q-a/550071/cn0549/rss?ContentTypeId=0</wfw:commentRss><description>&lt;p&gt;Hi&lt;/p&gt;
&lt;p&gt;I am FAE in Japanese distributor.&lt;/p&gt;
&lt;p&gt;My customer evaluate CN0549(CN0540+CN0532) now.&lt;/p&gt;
&lt;p&gt;Could you tell me how many g per LSB?&lt;/p&gt;
&lt;p&gt;Best regards&lt;/p&gt;
&lt;p&gt;N.Kokubo&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;</description></item></channel></rss>