Question
Can I generate:
Output1 : 26.214 MHzandOutput2 : 16.777216 MHz
Using:- Crystal 25MHz Tolérance:10ppm à 25°C / Stability :10ppm -20°Cà70°C /9pF / 70Ohms // MDX32Référence MDX32104-250GGE-T/R
- Oscillator : 25MHz Satbilité:25ppm à 25°C / -20°Cà70°C / HCMOS 3V3 /15pF
Reference M3320GAE-25.000MHz-T/RJittter
5ps RMS (1-sigma) max
1.5ps RMS (1-sigma) max, phase jitter in 10KHz ~20MHz Freq. Band
50ps peak-to-peak max
Answer
I ran the AD9578 eval software and it came up with 26.21399999923 (which is 0.02 ppb error) and 16.77721599987 MHz (which is 0.007 ppb error), and isat least a million times more accurate than the oscillator they want to use.