groupUrl: https://ez.analog.com/audio/
Analog.com Analog Dialogue Wiki English
Analog.com Analog Dialogue Wiki 简体中文
EngineerZone
EngineerZone
  • Site
  • User
  • Site
  • Search
  • User
EngineerZone
EngineerZone
  • Log in
  • Site
  • Search
  • Log in
  • Home
  • Blogs ⌵
  • Browse ⌵
    • All Groups
    • All Members
  • Support ⌵
    • 3D ToF Depth Sensing
    • A2B
    • Aerospace and Defense (ADEF)
    • Amplifiers
    • Analog Microcontrollers
    • Analysis Control Evaluation (ACE) Software
    • Audio
    • Clock and Timing
    • Condition-Based Monitoring
    • Data Converters
    • Design Tools and Calculators
    • Direct Digital Synthesis (DDS)
    • Embedded Vision Sensing
    • Energy Monitoring and Metering
    • FPGA Reference Designs
    • Industrial Ethernet
    • Interface and Isolation
    • Low Power RF Transceivers
    • MEMS Inertial Sensors
    • Motor Control Hardware Platforms
    • Optical Sensing
    • Power Management
    • Precision Technology Signal Chains
    • Processors and DSP
    • Reference Circuits
    • RF and Microwave
    • Signal Chain Power (SCP)
    • Switches/Multiplexers
    • Temperature Sensors
    • Video
    • Wide Band RF Transceivers
    • Wireless Sensor Networks Reference Library
  • About EZ
  • More
  • Cancel
  • 主页
  • 浏览 ⌵
    • 收件箱
    • 个人设置
    • 会员
    • 专区列表
  • 论坛专区 ⌵
    • 放大器专区
    • 精密转换器专区
    • 音频专区
    • ADE电能计量专区
    • MEMS和传感器专区
    • 接口和隔离专区
    • Power 中文专区
    • ADUC微处理器专区
    • 锁相环专区
    • 开关和多路复用器专区
    • 温度传感器
    • 基准电压源专区
    • 资源库
    • 论坛使用指南
    • 技术支持参考库
    • 在线研讨会
    • 论坛社群活动
    • 论坛激励活动
  • More
  • Cancel
Audio
Audio
Documents AD1992: Driving the input stage
  • Q&A
  • Documents
  • Video/Images
  • Tags
  • Managers
  • More
  • Cancel
  • New
Audio requires membership for participation - click to join
  • +Documents
  • +AD1853: FAQ
  • +AD73322: FAQ
  • +AD73311: FAQ
  • +AD73360: FAQ
  • +32-bit Audio Converters: FAQ
  • +AD1835: FAQ
  • +AD1836: FAQ
  • +AD1836A: FAQ
  • +AD1845: FAQ
  • +AD1852: FAQ
  • +AD1854: FAQ
  • +AD1862: FAQ
  • +AD1871: FAQ
  • +AD1877: FAQ
  • +AD1881: FAQ
  • +AD1896: FAQ
  • +AD1937: FAQ
  • +ad1938: FAQ
  • +AD1939: FAQ
  • +AD193x: FAQ
  • +AD1955: FAQ
  • +ad1970: FAQ
  • +AD1974: FAQ
  • +AD1981: FAQ
  • +AD1986: FAQ
  • -AD1992: FAQ
    • AD1992: Driving the input stage
  • +adau1381: FAQ
  • +ADAU1472: FAQ
  • +ADAU1761: FAQ
  • +ADAU1772: FAQ
  • +ADAU1966: FAQ
  • +ADMP441Z: FAQ
  • +ADMP504: FAQ
  • +CODEC: FAQ
  • +Digital Microphone: FAQ
  • +EVAL-MICT5818Z: FAQ
  • +HD Audio Codecs: FAQ
  • +MEMS mics: FAQ
  • +Power supplies, capacitors, and application schematics: FAQ
  • +REGEN and THERM: FAQ
  • +SigmaStudio: FAQ
  • +ssm2166: FAQ
  • +SSM2250: FAQ
  • +SSM2302: FAQ
  • +SSM2306: FAQ
  • +ssm2311: FAQ
  • +ssm2518: FAQ
  • +SSM2529: FAQ
  • +ssm2602: FAQ
  • +SSM2603: FAQ

AD1992: Driving the input stage

Q 

I would like to control the current (if not possible then the voltage)running
through the 2 voice coils by controlling both single ended inputs of the AD1992
using a DC coupled (no capacitor) AD5668 DAC.

- Is it possible to drive the inputs of the AD1992 directly with the AD5668 (it
looks OK since imput impedance of AD1992 is 20K and the DAC can source <30mA).
- What are the limitations for R and L of different voice coils I can use (to
ensure stable operation of the AD1992)?

 

A 

The input buffer of the AD1992 is an inverting amplifier with the non inverting
(+) input connected to Vdd/2, nominal. Therefore, to get zero output you need
to get the DAC to output Vdd/2. However the precise voltage used to bias the
input stage may have quite a large tolerance associated with it (+/-10% or
more) therefore it will require some adjustment to get the zero point exactly
right. Other than that the AD5668 should be able to drive the AD1992 with no
problems. It is an octal DAC - do you also need 8 channels of Class-D amplifier
i.e. 4 units?

Besides that, there are very few specifications relating to DC precision, so if
DC precision is important in your application you may have some problems with
the precision of the AD1992.

The stability of the AD1992 depends more on the gain settings (see page 14 of
the datasheet) than on the nature of the load.

If the output current exceeds 4A then the output protection will begin to
operate, so the load impedance and Transistor power supply should account for
this output current limitation.

  • ad1992
  • Share
  • History
  • More
  • Cancel
Comments
Anonymous
Related
 
社交网络
快速链接
  • 关于ADI
  • Partners
  • 模拟对话
  • 职业
  • 联系我们
  • 投资信息
  • 新闻中心
  • 质量和可靠性
  • 办事处与代理商
  • Analog Garage
语言
  • English
  • 简体中文
  • 日本語
  • Руccкий
电子快讯

欲获得最新ADI产品、设计工具、培训与活动的相关新闻与文章,请从我们的在线快讯中选出您感兴趣的产品类别,每月或每季度都会发送至您的收件箱。

订阅
Switch to mobile view
Analog Logo
© 1995 - 2022 Analog Devices, Inc. All Rights Reserved 沪ICP备09046653号-1
  • ©
  • 1995 - 2022 Analog Devices, Inc. All Rights Reserved
  • 沪ICP备09046653号-1
  • 网站地图
  • 隐私和保密政策
  • 隐私设置
  • 使用条款
 
Social
Quick Links
  • About ADI
  • Partners
  • Analog Dialogue
  • Careers
  • Contact us
  • Investor Relations
  • News Room
  • Quality & Reliability
  • Sales & Distribution
  • Analog Garage
Languages
  • English
  • 简体中文
  • 日本語
  • Руccкий
Newsletters

Interested in the latest news and articles about ADI products, design tools, training and events? Choose from one of our 12 newsletters that match your product area of interest, delivered monthly or quarterly to your inbox.

Sign Up
Switch to mobile view
Analog Logo
© 1995 - 2022 Analog Devices, Inc. All Rights Reserved 沪ICP备09046653号-1
  • ©
  • 1995 - 2022 Analog Devices, Inc. All Rights Reserved
  • 沪ICP备09046653号-1
  • Sitemap
  • Privacy & Security
  • Privacy Settings
  • Terms of use
EngineerZone Uses cookies to ensure you get the best experience in our community. For more information on cookies, please read our Privacy & Security Statement.